A toilet compartment is a partitioned space that is located within a toilet room, and that normally contains no more than one water closet....
Search Results "Wheelchair Seating Space"
-
11B-213.3.1 Toilet compartments
-
6c.
Is there at least a 30-inch by 48-inch clear floor space on the wheelchair lift? Yes _____ No _____...
-
11B-608.5.3 Alternate roll-in type shower compartments
wall or shall be located on the back wall opposite the seat 15 inches (381 mm) maximum, left or right of the centerline of the seat....
-
11B-809.9.1 Clear floor space
Clear floor spaces 30 inches (762 mm) by 48 inches (1219 mm), with centerlines aligned with the centerline of the work surface, appliance, sink or fixture, shall be provided in the following...
-
11B-809.9.1 Clear floor space
Clear floor spaces 30 inches (762 mm) by 48 inches (1219 mm), with centerlines aligned with the centerline of the work surface, appliance, sink or fixture, shall be provided in the following...
-
11B-304.4 Door swing
Doors shall be permitted to swing into turning spaces....
-
304.4 Door Swing
Doors shall be permitted to swing into turning spaces....
-
11B-304.4 Door swing
Doors shall be permitted to swing into turning spaces....
-
11B-304.4 Door swing
Doors shall be permitted to swing into turning spaces....
-
304.4 Door Swing
Doors shall be permitted to swing into turning spaces....
-
Width of Spaces [1012.3]
Parking spaces for vehicles other than RVs must be at least 16 feet wide. Parking spaces at least 16 feet wide can accommodate vans equipped with a lift or ramp....
-
241 and 612 Saunas and Steam Rooms
612 Saunas and Steam Rooms Section 241 of the 2010 Standards sets scoping for saunas and steam rooms and section 612 sets technical requirements including providing accessible turning space...
-
304.4 Door Swing
Doors shall be permitted to swing into turning spaces....
-
Chapter 9: Built-In Elements
Changes made to this section include: clarification of provisions for benches concerning clear floor or ground space (903.2), back support (903.4), and height (903.5) addition...
-
11B-805.2.3 Turning space
Turning space complying with Section 11B-304 shall be provided within the room....
-
11B-805.2.3 Turning space
Turning space complying with Section 11B-304 shall be provided within the room....
-
11B-805.2.3 Turning space
Turning space complying with Section 11B-304 shall be provided within the room....
-
Highest and Lowest Heights Obtained
The 5th percentile lowest and highest transfers attained were similar to the average WMD seat height (22.1 inch) for all protocols....
-
11B-604.3.1 Size
A minimum 60 inches (1524 mm) wide and 48 inches (1219 mm) deep maneuvering space shall be provided in front of the water closet....
-
5.2.3 Transfer Surface Measurement Recommendation for M301 and M302
Figure 5.2.3 below indicates how these width and depth dimensions are measured for MDE used by patients in supine, prone, or side-lying positions (M301) and the seated position (M302)...
- IPS Corporation Truebro® Lav Shield® Protective Lavatory Enclosure
-
11B-812.1 General
Where vehicle spaces and access aisles are marked with lines, measurements shall be made from the centerline of the markings....
-
11B-812.1 General
Where vehicle spaces and access aisles are marked with lines, measurements shall be made from the centerline of the markings....
-
11B-224.8.1 More than 25-bed sleeping rooms
In sleeping rooms with more than 25 beds, a minimum of 5 percent of the beds shall have clear floor space complying with Section 11B-806.2.3....