Horizontal openings in gratings and joints shall not permit passage of a sphere more than 13 mm (0.5 in) in diameter....
Search Results "Building Permit"
-
R302.7.3 Horizontal Openings
-
§ 36.302(c)(9)(i)
(i) A public accommodation shall make reasonable modifications in policies, practices, or procedures to permit the use of a miniature horse by an individual with a disability if the miniature...
-
303.1 General
Where changes in level are permitted in floor or ground surfaces, they shall comply with 303. EXCEPTIONS: 1. Animal containment areas shall not be required to comply with 303. 2....
-
§ 36.302(c)(7)
Individuals with disabilities shall be permitted to be accompanied by their service animals in all areas of a place of public accommodation where members of the public, program participants...
-
R405.3.4 Clearance Reduction
Between 230 mm (9 in) and 685 mm (2.25 ft) above the finish surface, the knee clearance shall be permitted to reduce at a rate of 25 mm (1 in) in depth for each 150 mm (6 in) in height....
-
1016.7.2 Cross Slope
Where the surface is other than asphalt, concrete, or boards, cross slopes not steeper than 1:20 are permitted when necessary for drainage....
-
1014.3.2 Slope
EXCEPTION: Where the floor surface is other than asphalt, concrete, or boards, slopes not steeper than 1:20 shall be permitted when necessary for drainage....
-
1016.8.3 Slope
EXCEPTION: Where the surface is other than concrete, asphalt, or boards, slopes not steeper than 1:20 shall be permitted when necessary for drainage....
-
11B-707.5.1 User control
Exception: Speech output for any single function shall be permitted to be automatically interrupted when a transaction is selected....
-
11B-812.3 Floor or ground surfaces
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted....
-
Welcome and Charge to Participants
you’re going to lose the building....
- Sargent HC 8800 Rim Exit Device
- Aluminum Heavy Duty Wheels n' Heels® Metro Grating
- Bobrick Reversible Folding Shower Seat B-5181
- Wingits Reversible L-shaped 26" x 22.5" Shower Seat
- Cal-Royal CR801 Series Hydraulic Door Closers
-
[2010 ADAS] 105.2.2 ASME
The building location, the elevator car number, and the need for assistance must be provided to authorized personnel answering the emergency call....
-
[2010 ADAS] 105.2.2 ASME
The building location, the elevator car number, and the need for assistance must be provided to authorized personnel answering the emergency call....
-
407.4.1 Car Dimensions
that provide a clear floor area of 16 square feet (1.5 m2) minimum and also provide an inside clear depth 54 inches (1370 mm) minimum and a clear width 36 inches (915 mm) minimum shall be permitted...
-
§100.203(c)
It is unlawful for the landlord to refuse to permit the tenant, at the tenant's own expense, from making the modifications necessary to add the grab bars....
-
Protrusion Limits: ADA Standard Section 307.2
Section 307.2 covers the current ADA Standards for protrusion limits.
-
Height: ADA Standard Section 704.4.1
wheelchair accessible telephone because the required 34 inches (865 mm) minimum keypad height can causes the highest operable part of the telephone, usually the coin slot, to exceed the maximum permitted...
-
Door and Signal Timing: ADA Standard Section 407.3.4
Section 407.3.4 covers the current ADA Standards for door and signal timing of elevator reopening devices.
-
11B-307.2 Protrusion limits
Exception: Handrails shall be permitted to protrude 4½ inches (114 mm) maximum. Advisory 11B-307.2 Protrusion limits....