(4) Establishing geographic boundaries or office location or residence requirements for access to or membership or participation in any multiple listing service, real estate brokers' organization...
Search Results "Drinking Fountain Spout Location"
-
§100.90(b)(4)
-
4.1.5(4) ELEMENTS, SPACES, AND COMMON AREAS
If elements, spaces, or common areas are located in the existing building and they are not provided in the addition, then consideration should be given to making those elements, spaces,...
-
4.1.1 General
In alterations, where a condition for exception in section 1.1 prohibits full compliance with a specific requirement for clear floor or ground space surface slope, size, or location, the...
-
F245.3 Outdoor Constructed Features in Common Use and Public Use Areas
At least 20 percent, but not less than one, of each type of outdoor constructed feature provided at each location is required to comply with the applicable technical requirements in 1011...
-
Low Energy Doors and Gates [§404.3]
Low Energy Doors and Gates [§404.3] Low energy doors and gates usually require activation by the user through a push plate or control and are often used in moderate traffic locations...
-
11B-241.1 General
Exception: Where saunas or steam rooms are clustered at a single location, no more than 5 percent of the saunas and steam rooms, but no fewer than one, of each type in each cluster shall...
-
§ 38.113(a)(1)
least one doorway, on each side of the car from which passengers board, of each car required to be accessible by §38.111(a) and where the spaces required by §38.111(d) of this part are located...
-
11B-802.3.1 Alignment
In row seating, companion seats shall be located to provide shoulder alignment with adjacent wheelchair spaces....
-
11B-802.3.1 Alignment
In row seating, companion seats shall be located to provide shoulder alignment with adjacent wheelchair spaces....
-
11B-241.1 General
Exception: Where saunas or steam rooms are clustered at a single location, no more than 5 percent of the saunas and steam rooms, but no fewer than one, of each type in each cluster shall...
-
233.3.1 Minimum Number: New Construction
requirements of 233.3.1.1 and 233.3.1.2 shall apply to the total number of residential dwelling units that are constructed under a single contract, or are developed as a whole, whether or not located...
-
1005.4 Clear Floor or Ground Space
At each location where there are railings, guards, or handrails complying with 1005.2.1, a clear floor or ground space complying with 305 shall be provided....
-
604.9.5 Flush Controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with 604.8.2....
-
802.3.1 Alignment
In row seating, companion seats shall be located to provide shoulder alignment with adjacent wheelchair spaces....
-
G. Access to Social Services, Temporary Lodging or Housing, and Other Benefit Programs
In addition, these services need to be offered in physically accessible locations so people with mobility disabilities can use them. ...
-
11B-213.2 Toilet rooms and bathing rooms
with Section 11B-603, altering existing toilet or bathing rooms shall not be required where a single unisex toilet room or bathing room complying with Section 11B-213.2.1 is provided and located...
-
B. Adoption and Implementation of ADA Accessibility Policy
The ADA Policy posted in Atlantis office locations must be printed in a bold font no smaller than 20 points on a contrasting background. ...
-
1023.9 Stairway identification signs
At the exit discharge level, the sign shall include a raised five pointed star located to the left of the identifying floor level....
-
11B-213.2 Toilet rooms and bathing rooms
Where multiple single user portable toilet or bathing units are clustered at a single location, 5 percent, but no fewer than one, of the toilet units and bathing units at each cluster shall...
-
11B-213.2 Toilet rooms and bathing rooms
altering existing toilet or bathing rooms shall not be required where a single unisex (single-user or family) toilet room or bathing room complying with Section 11B-213.2.1 is provided and located...
-
5.2 Q. If a building design contains a mix of single-story flats on grade and single-story flats located above grade over a public parking area, do the flats over the parking area have to be accessible?
A. No. In the example in the above question, because some single-story flats are situated on grade, these flats would be the ground floor dwelling units and would be required to be...
-
V. DEVELOPMENT OF DISABILITY-RELATED POLICIES AND PROCEDURES
concerns relating to that individual’s spinal cord injury or similar condition with the patient, including, but not limited to, concerns regarding bowel or bladder program, diet, eating/drinking...
-
11B-1005.4 Clear floor or ground space
At each location where there are railings, guards, or handrails complying with Section 11B-1005.2.1, a clear floor or ground space complying with Section 11B-305 shall be provided....
-
11B-220.1.3 Three or more automatic teller machines or fare machines
Where three or more automatic teller machines or fare machines are provided at a location, at least 50 percent shall comply with Sections 11B-707.2 through 11B-707.8 and the rest shall comply...