Upon presentation of security credential, the destination floor shall be confirmed by verbal announcement and on the display screen....
Search Results "Floor Identification"
-
11B-411.2.1.7.3 Assignment by security credential
-
11B-411.2.1.7.3 Assignment by security credential
Upon presentation of security credential, the destination floor shall be confirmed by verbal announcement and on the display screen....
-
Play Tables: ADA Standard Section 1008.4.3
EXCEPTION: Play tables designed and constructed primarily for children 5 years and younger shall not be required to provide knee clearance where the clear floor or ground space required...
-
11B-804.3 Kitchen work surface
In kitchens within multi-bedroom housing units and on floors containing accessible sleeping rooms with adaptable features in undergraduate student housing, at least one 30 inches (762 mm...
-
11B-604.9.6 Dispensers
The outlet of the dispenser shall be 14 inches (356 mm) minimum and 19 inches (483 mm) maximum above the finish floor....
-
11B-804.3 Kitchen work surface
In kitchens within multi-bedroom housing units and on floors containing accessible sleeping rooms with adaptable features in undergraduate student housing, at least one 30 inches (762 mm...
-
11B-611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (914 mm) maximum above the finish floor....
-
611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (915 mm) maximum above the finish floor....
-
410 Platform Lifts
Section 410 provides requirements for platform lifts and addresses floor surfaces, clear floor space, operable parts, and doors and gates....
-
Main Lobby
The 40 1/2" height of the main ticket counter exceeds the maximum allowable height of 36" above the finished floor. See Standards § 7.2(1). j....
-
Accessible Route
Interior accessible routes may include corridors, floors, ramps, elevators, lifts, and clear floor space at fixtures....
-
Scoping [4.1.3(10)]
Instead it requires access based on the number provided on each floor so that half (50%) are accessible to people who use wheelchairs....
-
Dispersion
For example, if a floor is occupied by separate tenancies, both types of units should be dispersed to serve occupants of each tenancy....
-
4.2.6* SIDE REACH
If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach allowed shall be 54 in (1370 mm) and the low side reach shall be no less than 9...
-
III-7.5140 Drinking fountains
Where there is only one drinking fountain on a floor, it must be accessible both to individuals who use wheelchairs and to those who have difficulty bending or stooping (for example, by...
-
1134A.6, Item 4
Grab bar reinforcement shall be installed continuous in the walls of showers 32 inches to 38 inches (813 mm to 965 mm) above the floor....
-
Protruding Objects [4.31.4]
., 27 inches high from the floor), can be a hazard to people with vision impairments....
-
4.7.1 General
In alterations, where a condition for exception in section 1.1 prohibits full compliance with a specific requirement for clear floor or ground space surface, slope, size, or location, the...
-
1134A.6, Item 4
Grab bar reinforcement shall be installed continuous in the walls of showers 32 inches to 38 inches (813 mm to 965 mm) above the floor....
-
11B-809.10.6.4 Reinforcement for grab bars
grabs bars shall comply with the following: Continuous reinforcement shall be installed in the walls of showers 30 inches (762 mm) maximum to 38 inches (965 mm) minimum above the finish floor...
-
611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (915 mm) maximum above the finish floor....
-
407.4.8.2.1 Signal Type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop....
-
206.2.3 Multi-Story Buildings and Facilities
However, if the laundry room on the first floor is restricted to use by residents on the first floor, and the second floor laundry room is for use by occupants of the second floor, then...