606.2 Clear Floor Space (Exception 3) This section requires clear floor space positioned for a forward approach and knee and toe clearance to be provided at lavatories and sinks....
Search Results "Accessible Element"
-
606.2 Clear Floor Space (Exception 3)
-
4.34.5.7 CLEAR FLOOR SPACE
Clear floor space at fixtures may overlap.
-
§35.130(f) (Section-by-Section Analysis)
Such measures may include the provision of auxiliary aids or of modifications required to provide program accessibility....
- Access Board: Automatic Door Controls
-
4.3.4 Passing Space
If an accessible route has less than 60 in (1525 mm) clear width, then passing spaces at least 60 in by 60 in (1525 mm by 1525 mm) shall be located at reasonable intervals not to exceed...
-
4.3.4 PASSING SPACE
If an accessible route has less than 60 in (1525 mm) clear width, then passing spaces at least 60 in by 60 in (1525 mm by 1525 mm) shall be located at reasonable intervals not to exceed...
-
After January 26, 1992
“Readily accessible to and usable by” means that the new or altered building must be built in strict compliance with either the ADA Standards for Accessible Design or UFAS....
- Power PDF Standard 2 Software
-
2012 Florida Accessibility Code for Building Construction Pocket Guide
When considering the accessibility and usability of movable elements not directly covered by the Standards, the Department of Justice has stated, “Once the construction or alteration of...
-
K. Ambulatory Stall
If there are more than 5 stalls in any restroom, is there one stall in addition to the large accessible stall, that is 36" wide, has 2 parallel grab bars at 33"-36" off the floor and has...
-
233.3.3 Additions
Residential dwelling units required to comply with 233.3.1.1 shall be on an accessible route as required by 206....
-
How to Use this Checklist
Obtain Floor Plan or Make Sketch A floor plan helps the surveyors to get organized and to know how many elements there are, such as entrances and toilet rooms. ...
- Neo-Metro Commercial Contour Urinal 8944 Series
-
233.3.3 Additions
Residential dwelling units required to comply with 233.3.1.1 shall be on an accessible route as required by 206....
- Businesses Inspected by a CASp - from DSA
-
11B-411.2.1.5 Button requirements
Keypad buttons, the accessibility function button, and additional hall call console buttons shall comply with Section 11B-411.2.1.5....
-
11B-411.2.1.5 Button requirements
Keypad buttons, the accessibility function button, and additional hall call console buttons shall comply with Section 11B-411.2.1.5....
-
28 CFR Parts 35 and 36, Nondiscrimination on the Basis of Disability by State and Local Governments and Places of Public Accommodation; Equipment and Furniture (ANPRM)
titles II and III of the Americans with Disabilities Act (ADA) to ensure that equipment and furniture used in programs and services provided by public entities and public accommodations are accessible...
-
11B-810.2.3 Connection
Bus stop boarding and alighting areas shall be connected to streets, sidewalks, or pedestrian paths by an accessible route complying with Section 11B-402....
-
11B-810.2.3 Connection
Bus stop boarding and alighting areas shall be connected to streets, sidewalks, or pedestrian paths by an accessible route complying with Section 11B-402....
-
3 [§ 4.3.7]
The cross slope of a curb ramp, or any accessible route, may not exceed 2 percent....
-
11B-203.9 Employee workstations
Employee workstations shall be on an accessible route complying with Division 4....
-
§ 35.151(h) Medical care facilities.
In addition, medical care facilities that do not specialize in the treatment of conditions that affect mobility shall disperse the accessible patient bedrooms required by section 223.2.1...
-
Ensuring Online Files and Documents are Accessible
The following sites and tools can help you create and maintain accessible web-based material: The American Council of the Blind’s publication, A Guide to Making Documents Accessible...