(2) Each one-bed room shall have a minimum clear floor space of 36 in (915 mm) along each side of the bed, and 42 in (1065 mm) between the foot of the bed and the wall....
Search Results "Toilet Room Door"
-
6.3(2)
-
408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
- Yale 1900 Series Traditional Door Closers
-
9.1.4(2) Equivalent Facilitation
For purposes of this section, it shall be deemed equivalent facilitation if the operator of a facility elects to limit construction of accessible rooms to those intended for multiple occupancy...
- Sargent 281 Series Cast Iron Door Closer
- Cal-Royal CR801 Series Hydraulic Door Closers
- Tormax Technologies iMotion® TN 110 In-Floor Swing Door Operator (High and Low Energy)
- Eliason Corporation SCP-8 High Pressure Laminate Traffic Door
-
A. Accessible Guestrooms
in Facility Accessible Rooms Rooms with Roll-in Showers 1 to 25 1 0 26 to 50 2 0 51 to 75 3...
-
11B-224.6 Storage
Fixed or built-in storage facilities within guest rooms required to provide mobility features shall comply with Section 11B-225....
-
11B-224.6 Storage
Fixed or built-in storage facilities within guest rooms required to provide mobility features shall comply with Section 11B-225....
- Yale 3000 Series Architectural Door Closer
-
Universal Design for Health Care Facilities
Universal Design for Health Care Facilities: Addressing Safety, Access to Care for a Diverse Patient Population Environment of Care® News, January 2009, Volume 12, Issue...
-
1011.4, Item 1
Each grade-level exterior exit door that is required to comply with Section 1011.1 shall be identified by a tactile exit sign with the word, “EXIT.”...
-
1013.4, Item 1
Each grade-level exterior exit door that is required to comply with Section 1013.1 shall be identified by a tactile exit sign with the word, “EXIT.”...
- Hager Companies Round Door Push/Pull Set 20
-
Section 35.151(h) Medical care facilities
When accessible rooms are not fully dispersed, a person with a disability is often placed in an accessible room in an area that is not medically appropriate for his or her condition, and...
-
Section 36.406(g) Medical Care Facilities
When accessible rooms are not fully dispersed, a person with a disability is often placed in an accessible room in an area that is not medically appropriate for his or her condition, and...
-
806.1 General
Transient lodging guest rooms shall comply with 806. Guest rooms required to provide mobility features shall comply with 806.2....
-
806.1 General
Transient lodging guest rooms shall comply with 806. Guest rooms required to provide mobility features shall comply with 806.2....
-
Scoping
Scoping requirements for guest rooms with mobility features and guest rooms with communication features are addressed at section 224.2 and section 224.4, respectively....
-
408.3.2.1 Power Operation
Swinging doors shall be power-operated and shall comply with ANSI/BHMA A156.19 (1997 or 2002 edition) (incorporated by reference, see "Referenced Standards" in Chapter 1)....
-
9.5.2(2)(a)
(a) at least one public entrance shall allow a person with mobility impairments to approach, enter and exit including a minimum clear door width of 32 in (815 mm)....
- Besam SL500 CGL Commercial Glass Entry Door - Fixed Sidelite SS BIM