11B-703.5.6 Height from finish floor or ground. Visual characters shall be 40 inches (1016 mm) minimum above the finish floor or ground. Exceptions: 1. Visual characters...
Search Results "Toilet Room Door"
Commonly Searched Documents
-
11B-703.5.6 Height from finish floor or ground
-
§ 38.107(a)(1)
(1) The minimum clear floor area shall be 35 inches by 60 inches. Permanently installed fixtures may overlap this area a maximum of 6 inches, if the lowest portion of the fixture is...
-
11B-703.5.6 Height from finish floor or ground
Visual characters shall be 40 inches (1016 mm) minimum above the finish floor or ground. Exceptions: Visual characters indicating elevator car controls shall not be required...
-
LaCantina Multi-slide Aluminum Wood Sliding Door System Pocket Door Model
Requires the Premium User plan or above. (Login or upgrade your account!)
-
11B-604.8.1.1 Size
When baby changing tables are provided within a multiple accommodation toilet room Section 11B-226.4 prohibits the installation in wheelchair accessible compartments....
- Norton Surface Mounted Medium Duty 8000 Series Door Closer
-
5.3.3.2 Location Where Walls Provided
Where walls or partitions are provided, the seat shall be positioned with a wall or partition to the rear and to one side of the seat for a left-hand or right-hand approach. The back...
-
11B-604.8.1.4 Toe clearance
11B-604.8.1.4 Toe clearance. At least one side partition shall provide a toe clearance of 9 inches (229 mm) minimum above the finish floor and 6 inches (152 mm) deep minimum beyond...
-
11B-604.8.1.4 Toe clearance
At least one side partition shall provide a toe clearance of 9 inches (229 mm) minimum above the finish floor and 6 inches (152 mm) deep minimum beyond the compartment-side face of...
- Allegion Falcon SC90 Series Surface Mounted Door Control
-
Visual Alarms, Notification Devices and Telephones [9.3] Auxiliary Alarms
Because guest room sizes are not large, it is required only that the signal, which is intended to alert persons who are awake, be visible in all areas of the room or unit....
-
Stanley SB600 Bifolding Door Bi-Fold Fold In Break Out
Requires the Premium User plan or above. (Login or upgrade your account!)
- Rockwood Manufacturing Company 35 Push & Pull Bar Set 3/8" x 1-1/4" Door Hardware
-
9.2.2(1)
(1) Accessible sleeping rooms shall have a 36 in (915 mm) clear width maneuvering space located along both sides of a bed, except that where two beds are provided, this requirement can be...
- Kawneer North America 1040 Sliding Mall Front Door
-
§ 36.406(e) Housing at a place of education.
subject to this section shall comply with the provisions of the 2010 Standards applicable to transient lodging, including, but not limited to, the requirements for transient lodging guest rooms...
- Allegion LCN 6030 Series Overhead Concealed Door Control
-
LaCantina Multi-slide Thermally Controlled Aluminum Sliding Door System Pocket Door Model
Requires the Premium User plan or above. (Login or upgrade your account!)
- Allegion Falcon SC60 Series Surface Mounted Door Closer
-
§ 36.406(c) Places of lodging
proposed standards shall comply with the provisions of the proposed standards that apply to transient lodging, including, but not limited to the requirements for transient lodging guest rooms...
-
9.5.2(2)(d)
(d) at least one common area which a person with mobility impairments can approach, enter and exit including a minimum clear door width of 32 in (815 mm)....
- BEA Inc. Jamb Style Door Access PTE (Push To Exit)
-
Sleeping Areas: ADA Standard Section 806.2.3
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed. The clear floor space shall be positioned for parallel approach to the side of...
-
11B-809.10.6.6 Controls
Controls and operating mechanisms shall comply with Section 11B-309.4.