Wheelchair spaces shall be dispersed horizontally. EXCEPTIONS: 1....
Search Results "Transfer Space"
-
221.2.3.1 Horizontal Dispersion
-
1133A.2, Item 3
A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows either a parallel or a forward approach shall be provided at the work surface required by Section 1133A...
-
1133A.2, Item 3
A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows either a parallel or a forward approach shall be provided at the work surface required by Section 1133A...
-
11B-405.2 Slope
EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes steeper than 1:12 complying with Table 405.2 where such slopes are necessary due to space...
-
11B-405.2 Slope
EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes steeper than 1:12 complying with Table 405.2 where such slopes are necessary due to space...
-
11B-405.2 Slope
EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes steeper than 1:12 complying with Table 405.2 where such slopes are necessary due to space...
-
CAL Green requires x number of EVSE per xxx number of spaces - each on its own 40 amp circuit. Some dual EVSE are on a single 40 amp circuit and split the 40 amp. Does this mean that half of those plugs don't comply with the required number?
RESPONSE: The California Green Code appears to require service panels, sub-panels, and raceway of sufficient capacity to accommodate 40 amp circuits rather than mandating one 40 amp...
-
Overview
requirements, which went into effect on March 15, 2011, address: Ticket Sales; Ticket Prices; Identification of Available Accessible Seating; Purchasing Multiple Tickets; Ticket Transfer...
-
1011.2.3 Slope
This section requires the slope of the clear ground space to not be steeper than 1:48 in any direction....
-
604.3.2 Overlap
around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear floor space...
-
Amusement Rides
Word Fillable Form (0.8MB) Word Non-Fillable Form (0.7MB) PDF Non-Fillable Form (0.5MB)
-
T211 Wheelchair Securement Systems
Wheelchair securement systems complying with the technical requirements in T603 must be provided at each wheelchair space....
-
F221.2.3.1 Horizontal Dispersion
Wheelchair spaces shall be dispersed horizontally. [ECTCR UFAS 4.33.3, 4.1.6(4)(f)(i)] EXCEPTIONS: 1....
-
1011.2.3 Slope
The slope of the clear ground space surface shall not be steeper than 1:48 in any direction....
-
1011.2.3 Slope
The slope of the clear ground space surface shall not be steeper than 1:48 in any direction....
-
B. M301 Diagnostic Equipment Used by Patients in a Supine, Prone, or Side-lying Position and M302 Diagnostic Equipment Used by Patients in a Seated Position
Sections M301 and M302, which ensure that patients can transfer from their mobility devices onto the diagnostic equipment, share many technical requirements....
-
11B-221.2.1.6 Specialty seating areas
In assembly areas, wheelchair spaces shall be provided in each specialty seating area that provides spectators with distinct services or amenities that generally are not available to other...
-
11B-221.2.1.6 Specialty seating areas
In assembly areas, wheelchair spaces shall be provided in each specialty seating area that provides spectators with distinct services or amenities that generally are not available to other...
-
11B-221.2.1.6 Specialty seating areas
In assembly areas, wheelchair spaces shall be provided in each specialty seating area that provides spectators with distinct services or amenities that generally are not available to other...
-
604.3.2 Overlap
around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear floor space...
-
§ 36.302(f)(4)(iii) Sales limited to fewer than four tickets
tickets to fewer than four seats per patron, then the public accommodation is only obligated to offer as many seats to patrons with disabilities, including the ticket for the wheelchair space...
-
604.3.2 Overlap
around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear floor space...
-
1012.3 Other Vehicles
This section requires parking spaces for vehicles, other than recreational vehicles, to be 16 feet wide minimum to accommodate vans equipped with a lift or ramp....