Is there a sign at each single pay phone or pay phone bank directing deaf persons to the location of a TTY for use at a pay telephone, if there are 4 or more pay phones on the site?...
Search Results "Dispenser Location"
-
4. TTY
-
12162(a)(3)(C) Limitation
Of the number of spaces required on a train by subparagraph (A), not more than two spaces to park and secure wheelchairs nor more than two spaces to fold and store wheelchairs shall be located...
-
4.1.2(5)(e) Valet parking
(e)* Valet parking: Valet parking facilities shall provide a passenger loading zone complying with 4.6.6 located on an accessible route to the entrance of the facility....
-
408.1 General
Where stationary ICT provides one or more display screens, at least one of each type of display screen shall be visible from a point located 40 inches (1015 mm) above the floor space where...
-
4.1.5(2) ACCESSIBLE ROUTE
If the only accessible entrance to the addition is located in the existing building or facility, then at least one accessible route shall comply with 4.3, Accessible Route, and shall provide...
-
4.34.5.4(5) Shower unit
Figure 48 Location of Grab Bars and Controls of Adaptable Bathtubs...
-
AMUSEMENT ATTRACTION
[DSA-AC] Any facility, or portion of a facility, located within an amusement park or theme park which provides amusement without the use of an amusement device....
-
CURB RAMP
A sloping pedestrian way, intended for pedestrian traffic, which provides access between a walk or sidewalk and a surface located above or below an adjacent curb face....
-
AMUSEMENT ATTRACTION
[DSA-AC] Any facility, or portion of a facility, located within an amusement park or theme park which provides amusement without the use of an amusement device....
-
1008.2.5.3 Handrails
Handrails shall not be required on ramps located within ground level use zones. 2. Handrail extensions shall not be required....
-
Amusement Attraction
Any facility, or portion of a facility, located within an amusement park or theme park which provides amusement without the use of an amusement device....
- Viking E-1600A-BLT-EWP Emergency Tower Phone with Blue LED Beacon and Strobe Light
- Viking E-1600-IP VoIP Emergency Phones with Built-in Auto Dialer and Digital Announcer
- Viking E-1600-45A-EWP Emergency Phones with Built-in Auto Dialer and Digital Announcer with Weather Protection
-
Accessible Fishing Piers and Platforms
percent (25%) of railings, guards, or handrails (if provided) to be at a 34-inch maximum height (so that a person seated in a wheelchair can cast a fishing line over the railing) and to be located...
-
Access Aisle
Section 502.3 of the 2010 Standards provides the flexibility necessary to permit designers and others to determine the most appropriate location of the accessible route to the accessible...
-
1136A.2 Switch and control heights
or switches intended to be used by the occupant of the room or area to control lighting and receptacle outlets, appliances, alarms or cooling, heating and ventilating equipment shall be located...
-
11B-221.2.3.2 Vertical dispersion
In addition, wheelchair spaces shall be located in each balcony or mezzanine that is located on an accessible route. Exceptions: 1. ...
-
Prevention of Fraud in Purchase of Tickets for Accessible Seating
stating that, if the user of the ticket does not need the specific features of the accessible seat, the venue may require the ticket holder to move to a different, non-accessible seating location...
-
Emergency Egress
Emergency Egress ADAAG requires that accessible seating be located on an accessible route which also serves as a means of egress....
-
11B-221.2.3.2 Vertical dispersion
In addition, wheelchair spaces shall be located in each balcony or mezzanine that is located on an accessible route. [2010 ADAS] Advisory 221.2.3.2 Vertical Dispersion. ...
-
1136A.2 Switch and control heights
or switches intended to be used by the occupant of the room or area to control lighting and receptacle outlets, appliances, alarms or cooling, heating and ventilating equipment shall be located...
-
11B-221.2.3.2 Vertical dispersion
In addition, wheelchair spaces shall be located in each balcony or mezzanine that is located on an accessible route. Advisory 11B-221.2.3.2 Vertical dispersion....
-
1136A.2 Switch and control heights
or switches intended to be used by the occupant of the room or area to control lighting and receptacle outlets, appliances, alarms or cooling, heating and ventilating equipment shall be located...