Signs shall be 60 inches (1525 mm) minimum above the finish floor or ground surface measured to the bottom of the sign....
Search Results "Court Floor Holding Cell"
-
11B-812.8.7 Location
-
11B-812.8.7 Location
Signs shall be 60 inches (1525 mm) minimum above the finish floor or ground surface measured to the bottom of the sign....
-
11B-307.3 Post-mounted objects
objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (686 mm) minimum and 80 inches (2032 mm) maximum above the finish floor...
- Georgia-Pacific enMotion® Automated Touchless Soap and Sanitizer Dispenser
-
G.
Later, the United States Court of Appeals for the Fifth Circuit so held in Lara v. Cinemark USA, Inc., 207 F.3rd 783 (5th Cir.), cert. denied, 531 U.S. 944 (2000)....
-
§35.164 Duties
Like paragraph (a)(3), it limits the obligation of the public entity to ensure effective communication in accordance with Davis and the circuit court opinions interpreting it....
-
B. PRELIMINARY ISSUES
Before reaching the question of whether Kirola has Article III standing, the Court addresses four preliminary contentions concerning the constellation of evidence which may be considered...
-
28. Q: Does the United States ever participate in lawsuits brought by private citizens?
The Department sometimes participates in private suits either by intervention or as amicus curiae -- "friend of the court."...
-
12101(a)(3)
. 110-325, § 2, Sept. 25, 2008, 122 Stat. 3553, provided that: (3) while Congress expected that the definition of disability under the ADA would be interpreted consistently with how courts...
-
§35.175 Attorney's fees (Section-by-Section Analysis)
(Section-by-Section Analysis) Section 35.175 states that courts are authorized to award attorneys fees, including litigation expenses and costs, as provided in section 505 of the Act....
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor....
-
11B-1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (279 mm) minimum and 18 inches (457 mm) maximum measured to the top of the surface from the ground or floor surface....
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor....
-
11B-608.10 Soap dish
Where a soap dish is provided, it shall be located on the control wall at 40 inches (1016 mm) maximum above the shower floor, and within the reach limits from the seat....
-
11B-1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (279 mm) minimum and 18 inches (457 mm) maximum measured to the top of the surface from the ground or floor surface....
-
Drinking Fountains for Standing Persons: ADA Standard Section 602.7
Section 602.7 covers the current ADA Standards for drinking fountains for standing persons.
-
Height: ADA Standard Section 1008.3.1.2
The height of transfer platforms shall be 11 inches (280 mm) minimum and 18 inches (455 mm) maximum measured to the top of the surface from the ground or floor surface....
-
11B-608.10 Soap dish
Where a soap dish is provided, it shall be located on the control wall at 40 inches (1016 mm) maximum above the shower floor, and within the reach limits from the seat....
-
11B-602.7 Drinking fountains for standing persons
Spout outlets of drinking fountains for standing persons shall be 38 inches (965 mm) minimum and 43 inches (1092 mm) maximum above the finish floor or ground....
-
Height: ADA Standard Section 407.3.3.1
Section 407.3.3.1 covers the current ADA Standards for the height requirements of an elevators reopening device.
-
11B-809.10.7.5 Controls
Controls shall be mounted 44 inches (1118 mm) maximum above the finish floor. The force required to activate controls shall be 5 pounds (22.2 mm) maximum....
-
11B-809.10.7.5 Controls
Controls shall be mounted 44 inches (1118 mm) maximum above the finish floor. The force required to activate controls shall be 5 pounds (22.2 mm) maximum....
-
11B-602.7 Drinking fountains for standing persons
Spout outlets of drinking fountains for standing persons shall be 38 inches (965 mm) minimum and 43 inches (1092 mm) maximum above the finish floor or ground....
-
Safe Harbor
Examples A public university library built in 1998 has light switches at 53 inches above the floor....