Where drains are provided, grate openings shall be ¼ inch (6.4 mm) maximum and flush with the floor surface....
Search Results "Clear Opening"
-
11B-608.9 Shower floor or ground surface
-
404.2.8.1 Door Closers and Gate Closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
804.6.2 Operable Parts
Bottom-hinged appliance doors, when in the open position, shall not be required to comply with 309.3....
-
5.3.3.3 Location Where Walls Not Provided
Where walls or partitions are not provided, the seat shall be positioned in a corner of the clear floor or ground space required by 5.3.2 for a left-hand or right-hand approach. ...
-
5.3.3.3 Location Where Walls Not Provided
Where walls or partitions are not provided, the seat shall be positioned in a corner of the clear floor or ground space required by 5.3.2 for a left-hand or right-hand approach....
-
Can handrails overlap ramp landings?
Along runs and landings, the minimum clear width must be measured between the leading edge of handrails....
-
11B-406.5.10 Diagonal curb ramps
The bottom of diagonal curb ramps shall have a clear space 48 inches (1220 mm) minimum outside active traffic lanes of the roadway....
-
11B-406.5.10 Diagonal curb ramps
The bottom of diagonal curb ramps shall have a clear space 48 inches (1220 mm) minimum outside active traffic lanes of the roadway....
-
11B-608.2.1 Transfer type shower compartments
Transfer type shower compartments shall be 36 inches (914 mm) by 36 inches (914 mm) clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch (914...
-
11B-608.2.1 Transfer type shower compartments
Transfer type shower compartments shall be 36 inches (914 mm) by 36 inches (914 mm) clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch (914...
-
Expert Report of Jeromy G. Murphy, American Construction Investigations, LTD (August 6, 2018)
Building Entrance: One side of the double leaf doors at the designated accessible entrance does not provide at least 32 inches clear passage width when the door is open 90 degrees (1991...
- Magnuson Group CUBIC SOISTES Magazine Stand
-
1002.4.4.1 Width and Length
Wheelchair spaces shall provide a clear width of 30 inches (760 mm) minimum and a clear length of 48 inches (1220 mm) minimum measured to 9 inches (230 mm) minimum above the floor surface...
-
407.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
11B-810.10 Track crossings
Exception: Openings for wheel flanges shall be permitted to be 2½ inches (64 mm) maximum. FIGURE 11B-810.10 (EXCEPTION) TRACK CROSSINGS...
-
607.7 Bathtub Enclosures
Enclosures on bathtubs shall not have tracks installed on the rim of the open face of the bathtub. [ECTCR UFAS 4.20.7]...
-
§27.71(k)(5)(iii) Captioning.
Multimedia content that contains speech or other audio information necessary for the comprehension of the content must be open or closed captioned....
-
§ 27.71(k)(5)(iii) Captioning
Multimedia content that contains speech or other audio information necessary for the comprehension of the content must be open or closed captioned....
-
Wheelchair accessible seating is required. At least one percent of the seating must be wheelchair seating locations.
Each wheelchair seating location is an open, level space that accommodates one person using a wheelchair and has a smooth, stable, and slip-resistant surface....
-
g-v
If the answers to questions g-ii thru g-iv are No, can the door be propped open? ...
-
Gates and Barriers on Trails
If gates or barriers are constructed to control access to trails, include openings wide enough to allow hiker passage....
-
4.13.10* Door Closers
If a door has a closer, then the sweep period of the closer shall be adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3 in (...
-
Automatic Door
A door equipped with a power-operated mechanism and controls that open and close the door automatically upon receipt of a momentary actuating signal....
-
4.13.10* DOOR CLOSERS
If a door has a closer, then the sweep period of the closer shall be adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3 in (...