Ramps that change direction between runs at landings shall have a clear landing 60 inches (1525 mm) minimum by 72 inches (1829 mm) minimum in the direction of downward travel from the upper...
Search Results "Clear Opening"
Commonly Searched Documents
-
11B-405.7.4 Change in direction
-
11B-405.7.4 Change in direction
Ramps that change direction between runs at landings shall have a clear landing 60 inches (1525 mm) minimum by 72 inches (1829 mm) minimum in the direction of downward travel from the upper...
-
1015.1 General
The technical requirements address the clear ground space (1015.2) and viewing space (1015.3) at distinct viewing locations; the turning space within viewing areas (1015.4); and the surface...
-
4.5.1 General
In alterations, where a condition for exception in section 1.1 prohibits full compliance with a specific requirement for clear floor or ground space surface, slope, size, or location, the...
-
810.2.2 Dimensions--Modification to 810.2.2 of Appendix D to 36 CFR Part 1191
810.2.2 Dimensions--Modification to 810.2.2 of Appendix D to 36 CFR Part 1191 Bus boarding and alighting areas shall provide a clear length of 96 inches (2440 mm), measured perpendicular...
-
Microsoft Word implementation
Right click the image and select Size… Open the Alt Text Tab and type in the appropriate alt-text....
-
e-ii
[ADA Standards § 4.10.9, Fig. 22] Yes No Note: See Figure 22 for acceptable floor and opening dimensions....
-
C.8 - Are Section 508 access requirements satisfied if the agency provides such access following a request for it, as opposed to in anticipation of a request for access?
For example, the production of a training video, which is covered by the Section 508 standards, must include the incorporation of open or closed captioning and audio description during the...
-
E. Key Reach Range
If there is key card controlled door hardware on building entrances, is the key card reader positioned so persons who use wheelchairs may approach and operate the opener (48" high maximum...
-
11B-604.9.5 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
1008.1.9.7, Item 5
THIS DOOR WILL OPEN IN 15 [30] SECONDS ALARM WILL SOUND” Sign lettering shall be at least 1 inch (25 mm) in height and shall have a stroke of not less than 1/8 inch (3.2 mm)....
-
4.1.6(3)(c)(iii)
For example, an elevator of 47 in by 69 in (1195 mm by 1755 mm) with a door opening on the narrow dimension, could accommodate the standard wheelchair clearances shown in Figure 4....
-
D3. Door Hardware
[ADA Stds 4.13.9] Yes _____ No _____ If No, leave door propped open, add new accessible hardware, or adapt/replace hardware....
-
5b.
[ADA Stds 4.10.9] Note: See Figure 22 for acceptable floor and opening dimensions....
-
608.5.1 Transfer Type Shower Compartments
mm) minimum and 48 inches (1220 mm) maximum above the shower floor and shall be located on the control wall 15 inches (380 mm) maximum from the centerline of the seat toward the shower opening...
-
Scoping [4.1.3(5)]
elevators only in providing access to: performing areas in assembly occupancies wheelchair seating locations in assembly occupancies incidental space or rooms not open...
-
11B-611.4 Height
Front loading machines shall have the bottom of the opening to the laundry compartment located 15 inches (381 mm) minimum and 36 inches (914 mm) maximum above the finish floor....
-
11B-604.7.2 Disposal units
The disposal unit shall be located below the grab bar, with the opening of the disposal unit 19” minimum (483 mm) above the finish floor....
-
§ 38.119(b)
(b) The doorways of cars not operating at lighted station platforms shall have outside lights which, when the door is open, provide at least 1 foot-candle of illumination on the station...
-
11B-608.5.1 Transfer type shower compartments
mm) minimum and 48 inches (1219 mm) maximum above the shower floor and shall be located on the control wall 15 inches (380 mm) maximum from the centerline of the seat toward the shower opening...
-
11B-604.9.5 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
Requirements for Platform Lifts
Platform Lift Clear Floor Space and Doors/ Gates...
-
11B-904.4 Sales and service counters
the number of existing mail boxes, the counter shall be permitted to have a portion which is 24 inches (610 mm) long minimum complying with Section 11B-904.4.1 provided that the required clear...
-
M303.2.3 Wheelchair Spaces / Depth of Wheelchair Spaces for front or Rear Entry
2004 ADA and ABA Accessibility Guidelines that allow accessible routes, which normally must be 36 inches wide minimum, to be 32 inches wide minimum for short distances such as at door openings...