Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (864 mm) maximum...
Search Results "Adjustable Height Exam Table"
Commonly Searched Documents
-
11B-308.3.2 Obstructed high reach
-
ASME
/CSA B44-16: Safety Code for Elevators and Escalators 907.3.3, 911.1.6, 1009.4.1, 11B-407.1, 11B-407.1.1, 11B-407.4.9, 11B-408.1, 11B-409.1, 11B-411.1, 11B-810.9, 1607.10.1, 3001.2, Table...
- Aquatic Access Pool Lift IGAT-180/135
-
309 Operable Parts
Specifications for operable parts address clear floor space, height, and operating characteristics. Operable parts are required to be located with the reach ranges specified in 308....
-
407.8.3 Forward Reach
Where a forward reach allows a reach over a portion of the ICT, the height of that portion of the ICT shall be 34 inches (865 mm) maximum....
-
4.13.8* Thresholds at Doorways
Thresholds at doorways shall not exceed 3/4 in (19 mm) in height for exterior sliding doors or 1/2 in (13 mm) for other types of doors....
-
407.12.3 Forward Reach
Where a forward reach allows a reach over a portion of the ICT, the height of that portion of the ICT shall be 34 inches (865 mm) maximum....
-
4.9.2 TREADS AND RISERS
On any given flight of stairs, all steps shall have uniform riser heights and uniform tread widths....
-
4.13.8* THRESHOLDS AT DOORWAYS
Thresholds at doorways shall not exceed 3/4 in (19 mm) in height for exterior sliding doors or 1/2 in (13 mm) for other types of doors....
-
407.12.3.2.2 Knee and Toe Space
Toe space shall be permitted to provide a clear height of 9 inches (230 mm) minimum above the floor and a clear depth of 6 inches (150 mm) maximum from the vertical reference plane toward...
-
705.1.1 Dome Size
a base diameter of 0.9 inch (23 mm) minimum and 1.4 inches (36 mm) maximum, a top diameter of 50 percent of the base diameter minimum to 65 percent of the base diameter maximum, and a height...
-
705.1.1 Dome Size
a base diameter of 0.9 inch (23 mm) minimum and 1.4 inches (36 mm) maximum, a top diameter of 50 percent of the base diameter minimum to 65 percent of the base diameter maximum, and a height...
-
1132A.4, Item 2
., wood decking with spaces) shall be the same level as the interior landing, except that secondary exterior doors may have no more than ½ inch (12.7 mm) of change in height between floor...
-
Public Way
open to the outside air leading to a public street, which has been deeded, dedicated or otherwise permanently appropriated to the public for public use and which has a clear width and height...
-
Forward Approach
Forward Approach A maximum height of 48 inches is required for a forward reach....
-
1132A.4, Item 2
., wood decking with spaces) shall be the same level as the interior landing, except that secondary exterior doors may have no more than ½ inch (12.7 mm) of change in height between floor...
-
Performance for Surface Firmness and Stability
Table 5 Firmness and Stability by Surface Type N Mean Std. Devi-ation Std. Error Min. Max....
-
Three-Point Turn
The AASHTO Guide for the Development of Bicycle Facilities (pp. 35-36) recommends a minimum paved width of 300 cm (120 inches) for a two-way shared use path.(2) Table 18 shows that the mean...
-
B. TERMS OF AGREEMENT
Title III of the ADA as they apply to healthcare facilities and on techniques for safely assisting individuals with mobility disabilities to transfer to imaging equipment or examination tables...
-
11B-228.3.2.1 Public use or common use EVCS
Where EVCS are provided for public use or common use, EVCS complying with Section 11B-812 shall be provided in accordance with Table 11B-228.3.2.1....
-
404.2.4.1 Swinging Doors and Gates
Swinging doors and gates shall have maneuvering clearances complying with Table 404.2.4.1....
-
224.2 Guest Rooms with Mobility Features
In transient lodging facilities, guest rooms with mobility features complying with 806.2 shall be provided in accordance with Table 224.2....
-
407.4.1 Car Dimensions
Inside dimensions of elevator cars and clear width of elevator doors shall comply with Table 407.4.1....
-
404.2.4.1 Swinging Doors and Gates
Swinging doors and gates shall have maneuvering clearances complying with Table 404.2.4.1....