The lift shall incorporate an emergency method of deploying, lowering to ground level with a lift occupant, and raising and stowing the empty lift if the power to the lift fails....
Search Results "Character Height (Raised)"
-
§ 38.83(b)(3) Emergency operation
-
808.3 Clear Floor Space
EXCEPTION: In alterations, wheelchair spaces are not required to be located within the defined area of raised jury boxes or witness stands and shall be permitted to be located outside these...
-
1016.5 Obstacles
Obstacles on outdoor recreation access routes, passing spaces, and resting intervals shall not exceed 1/2 inch (13 mm) in height measured vertically to the highest point....
-
11B-225.2.3 Library book stacks
ETA Editor's Note The ADA Advisory identifies library shelving as self-service shelving, which does not have a height limitation....
-
407.8.3.2.2 Knee and Toe Space under ICT with Obstructed Forward Reach
Toe space shall be permitted to provide a clear height of 9 inches (230 mm) minimum above the floor and a clear depth of 6 inches (150 mm) maximum from the vertical reference plane toward...
-
1016.5 Obstacles
Obstacles on outdoor recreation access routes, passing spaces, and resting intervals shall not exceed 1/2 inch (13 mm) in height measured vertically to the highest point....
-
3.3.15.3 Side (lateral) reach – over an obstruction depth of 610 mm
obstruction depth of 610 mm The vast majority of WhMD users in our study that displayed some reach capability could not reach at or beyond a 610 mm (24 in.) obstacle, regardless of height...
-
§ 38.23(d)(4) Orientation
Additional securement devices or systems shall secure the wheelchair or mobility aid facing forward, or rearward with a padded barrier, extending from a height of 38 inches from the vehicle...
-
11B-225.2.3 Library book stacks
ETA Editor's Note The ADA Advisory identifies library shelving as self-service shelving, which does not have a height limitation....
-
R405.3.4 Clearance Reduction
Between 230 mm (9 in) and 685 mm (2.25 ft) above the finish surface, the knee clearance shall be permitted to reduce at a rate of 25 mm (1 in) in depth for each 150 mm (6 in) in height....
-
Do drinking fountains pose hazards as protruding objects?
Cantilevered units at standard heights for people who stand must be recessed or protected as protruding objects....
- Federal Elevator 360 Passenger Elevator
-
11B-206.2.6 Performance areas
Performance areas, including but not limited to, stages, platforms and orchestra pits, are treated as raised or lowered areas within a given story and all are required to be accessible by...
-
11B-206.2.6 Performance areas
Performance areas, including but not limited to, stages, platforms and orchestra pits, are treated as raised or lowered areas within a given story and all are required to be accessible by...
-
306.3.4 Clearance Reduction
inches (230 mm) and 27 inches (685 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches (150 mm) in height...
-
Introduction
Footrest clearance height and depth...
-
306.3.4 Clearance Reduction
inches (230 mm) and 27 inches (685 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches (150 mm) in height...
-
306.3.4 Clearance Reduction
inches (230 mm) and 27 inches (685 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches (150 mm) in height...
-
306.3.4 Clearance Reduction
inches (230 mm) and 27 inches (685 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches (150 mm) in height...
- Guldmann GLS5 Active lifter
-
Section 36.303(g)(1) Open Movie Captioning
The final rule defines “open movie captioning” as “the written on-screen display of a movie's dialogue and non-speech information, such as music, the identity of the character who is speaking...
- CalCasp Training: Advanced Scoping
- Symmetry Vertical Platform Lift VPC-EL
-
5.3.6 Entrance
Exception: Where bedrock, perma-frost or other environmental conditions prohibit a level entry or the toilet design (such as a composting toilet) necessitates a raised toilet structure,...