Based on that review, the Department has found that many detention and correctional facilities have too few or no accessible cells, toilets, and shower facilities to meet the needs of their...
Search Results "Shower Control"
Commonly Searched Documents
-
Section 35.152 Detention and correctional facilities—program requirements (Section-by-Section Analysis)
-
Courtesy Phones
Such phones are subject to requirements for wheelchair access and volume controls, but they are not covered by TTY requirements, which apply only to public pay telephones....
-
§382.57(c)(5)(ii)(B) Speaker volume
Where sound is delivered through speakers on the automated kiosk, incremental volume control must be provided with output amplification up to a level of at least 65 dB SPL....
-
Military Installation
Military installation does not include any facility used primarily for civil works, rivers and harbors projects, or flood control projects. ...
-
§ 382.57(c)(5)(ii)(B) Speaker volume
Where sound is delivered through speakers on the automated kiosk, incremental volume control must be provided with output amplification up to a level of at least 65 dB SPL....
-
7. Clear Width
accessible guestrooms arranged so that persons who use wheelchairs, crutches and other mobility aids can approach and use beds; bathrooms; closets; heating, air conditioning and drapery controls...
-
Dispensers [4.16.6]
Dispensers must provide continuous paper flow; those that have separate sheets or that control delivery are prohibited because they require repetitive hand motion and pinching and are not...
-
Equipment for Persons with Vision Impairments [4.34.5]
Braille instructions and control labels are commonly provided (Braille output is not required). Audible devices and handsets can also provide access while maintaining privacy....
-
11B-604.7.1 Dispensers
Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow....
-
11B-607.4.1.1 Back wall
Each grab bar shall be installed 15 inches (381 mm) maximum from the head end wall and 12 inches (305 mm) maximum from the control end wall....
-
810.2.2 Dimensions--Modification to 810.2.2 of Appendix D to 36 CFR Part 1191
Public entities shall ensure that the construction of bus boarding and alighting areas comply with 810.2.2, to the extent the construction specifications are within their control....
-
11B-604.7.1 Dispensers
Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow....
- DORMA 8900 Series Door Closer
-
NFPA
State Fire Marshal listed for use with the control unit....
-
Door King Inc. 6004 Column Mount Swing Gate Operator Solar Powered
Requires the Registered User plan or above. Login!
-
607.4.2.1 Back Wall
Each grab bar shall be 24 inches (610 mm) long minimum and shall be installed 24 inches (610 mm) maximum from the head end wall and 12 inches (305 mm) maximum from the control end wall....
-
11B-407.2.1.4 Location
A destination-oriented elevator system provides lobby controls enabling passengers to select floor stops, lobby indicators designating which elevator to use, and a car indicator designating...
-
607.4.1.1 Back Wall
Each grab bar shall be installed 15 inches (380 mm) maximum from the head end wall and 12 inches (305 mm) maximum from the control end wall. [ECTCR UFAS 4.34.5.4(3), Fig. 48(b)]...
-
703.4.1 Height above Finish Floor or Ground
[ECTCR UFAS 4.30.6] EXCEPTION: Tactile characters for elevator car controls shall not be required to comply with 703.4.1....
-
604.9.6 Dispensers
Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow....
-
Set the Automatic Volume Adjustment
If volumes are adequate in quiet conditions, but do not increase enough or quickly enough when ambient noise increases, the microphone sensitivity, or automatic gain control, may need to...
-
11B-607.4.2.1 Back wall
Each grab bar shall be 24 inches (610 mm) long minimum and shall be installed 24 inches (610 mm) maximum from the head end wall and 12 inches (305 mm) maximum from the control end wall....
-
607.4.2.1 Back Wall
Each grab bar shall be 24 inches (610 mm) long minimum and shall be installed 24 inches (610 mm) maximum from the head end wall and 12 inches (305 mm) maximum from the control end wall....