Section 608.5.1 covers the current ADA Standards for controls in transfer type shower compartments.
Search Results "Shower Control"
Commonly Searched Documents
-
Transfer Type Shower Compartments: ADA Standard Section 608.5.1
-
Standard Roll-In Type Shower Compartments: ADA Standard Section 608.5.2
Section 608.5.2 covers the current ADA Standards for controls in standard roll-in type shower compartments.
-
Alternate Roll-In Type Shower Compartments: ADA Standard Section 608.5.3
Section 608.5.3 covers the current ADA Standards for controls in alternate roll-in type shower compartments.
-
Controls: ADA Standard Section 608.5
Section 608.5 covers the current ADA Standards for controls in shower compartments.
-
Shower Spray Unit and Water: ADA Standard Section 608.6
Section 608.6 covers the current ADA Standards for the shower spray units and water in shower compartments.
-
11B-608.5 Controls
Controls, faucets, and shower spray units shall comply with Section 11B-309.4. Controls and faucets shall allow the user to close and open the water supply....
-
Shower Compartment Seats: ADA Standard Section 610.3
Section 610.3 covers the current ADA Standards for shower compartment seats.
-
11B-608.5.1 Transfer type shower compartments
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1219 mm...
-
Shower Enclosures: ADA Standard Section 608.8
Section 608.8 covers the current ADA Standards for enclosures for shower compartments.
-
11B-608.5.2 Standard roll-in type shower compartments
In standard roll-in type shower compartments, the controls, faucets, and the shower spray unit shall be located on the back wall of the compartment adjacent to the seat 16 inches (406 mm...
-
Shower Spray Unit and Water: ADA Standard Section 607.6
Section 607.5 covers the current ADA Standards for bathtub shower spray units and the water temperature of the spray units.
-
11B-608.5.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located on the side wall of the compartment adjacent to the 16 inches (406 mm) minimum...
-
Standard Roll-In Type Shower Compartments: ADA Standard Section 608.3.2
Section 608.3.2 covers the current ADA Standards for grab bars in standard roll-in type shower compartments.
-
Alternate Roll-In Type Shower Compartments: ADA Standard Section 608.3.3
Section 608.3.3 covers the current ADA Standards for grab bars in alternate roll-in type shower compartments.
-
Controls [4.21.5]
Controls [4.21.5] Controls and shower units can be located on any wall but where a folding seat is provided they must be located to be within reach of a person on the seat....
-
Location of Controls
In transfer compartments, controls, faucets, and shower spray units were to be located no more than 15 inches on either side of the seat centerline, according to the proposed rule (608.5.1...
-
Transfer Type Shower Compartments: ADA Standard Section 608.3.1
Section 608.3.1 covers the current ADA Standards for grab bars in transfer type shower compartments.
-
Transfer Type Shower Compartments: ADA Standard Section 608.2.1
Section 608.2.1 covers the current ADA Standards for the size and clearances of transfer type shower compartments.
-
9. Faucet Controls
Do roll-in showers have faucet controls that are easily operable with one hand (i.e.: levers, wrist blades, single arm, etc.) without tight grasping, pinching or twisting of the wrist?...
-
11B-809.10.6.6 Controls
Controls and operating mechanisms shall comply with Section 11B-309.4....
-
11B-608.6 Shower spray unit and water
A shower spray unit with a hose 59 inches (1499 mm) long minimum that can be used both as a fixed-position shower head and as a hand-held shower shall be provided....
-
Size and Clearances for Shower Compartments: ADA Standard Section 608.2
Section 608.2 covers the current ADA Standards for the size and clearances of shower compartments.
-
Shower Compartments: ADA Standard Section 608
Section 608 covers the current ADA Standards for shower compartments.
-
4.21.5 Controls
4.21.5 Controls. None of the respondents indicated that there were any variations from ADAAG regarding the controls....