Single occupant structures accessed only by passageways below grade or elevated above standard curb height, including but not limited to, toll booths that are accessed only by underground...
Search Results "Curb Ramp Width"
-
11B-203.6 Single occupant structures
-
11B-203.6 Single occupant structures
Single occupant structures accessed only by passageways below grade or elevated above standard curb height, including but not limited to, toll booths that are accessed only by underground...
-
808.2 Turning Space
Where provided, areas that are raised or depressed and accessed by ramps or platform lifts with entry ramps shall provide unobstructed turning space complying with 304....
-
11B-411.4.1 Car dimensions
Inside dimensions of elevator cars and clear width of elevator doors shall comply with Section 11B-407.4.1....
-
11B-411.4.1 Car dimensions
Inside dimensions of elevator cars and clear width of elevator doors shall comply with Section 11B-407.4.1....
-
11B-411.4.1 Car dimensions
Inside dimensions of elevator cars and clear width of elevator doors shall comply with Section 11B-407.4.1....
-
M301.2.2 Transfer Surface Size
When the transfer surface is located as described above in “A”, the width of the patient scanning/imaging table (side to side) at the designated transfer location should be 28 inches minimum...
-
1006.3.2 Barriers
Where curbs or other constructed barriers prevent golf cars from entering a fairway, openings 60 inches (1525 mm) wide minimum shall be provided at intervals not to exceed 75 yards (69 m...
-
608.1 General
Shower stalls that are 60 inches (1525 mm) wide and have no curb may increase the usability of a bathroom because the shower area provides additional maneuvering space....
-
608.1 General
Shower stalls that are 60 inches (1525 mm) wide and have no curb may increase the usability of a bathroom because the shower area provides additional maneuvering space....
-
19.1 Q. If a sliding door track has a threshold of 3/4, does this trigger requirements for ramps?
A. No. The Guidelines at Requirement 4 provide that thresholds at doors, including sliding door tracks, may be no higher than 3/4 and must be beveled with a slope no greater than 1:2.
-
11B-705.1.2.5 Blended transitions
Detectable warnings at blended transitions shall be 36 inches (914 mm) in width....
-
3306.2 Walkways
Walkways shall be of sufficient width to accommodate the pedestrian traffic, but in no case shall they be less than 4 feet (1219 mm) in width....
-
Handrails
Handrails Pool stairs must have handrails with a minimum width between the rails of 20 inches and a maximum of 24 inches....
-
3306.2 Walkways
Walkways shall be of sufficient width to accommodate the pedestrian traffic, but in no case shall they be less than 4 feet (1219 mm) in width....
-
§ 38.101(a)
(a) Any stepwell or doorway with a lift, ramp or bridge plate shall have, when the door is open, at least 2 footcandles of illumination measured on the step tread, ramp, bridge plate, or...
-
11B-608.2.2 Standard roll-in type shower compartments
shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides with a full opening width...
-
11B-608.2.2 Standard roll-in type shower compartments
shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides with a full opening width...
-
2. Shoulder Breadth
Shoulder Breadth Shoulder breadth tends to be slightly greater than hip or thigh breadth and hence was used as an estimate for the width of an examination table when in a reclined position...
-
Taking Measurements
Measuring slope using a 24-inch level and tape measure Using the Tape Measure When measuring the width of a parking space or access aisle, the width of an accessible route or the height...
-
§ 38.119(a)
(a) Any stepwell, or doorway with a lift, ramp or bridge plate, shall have, when the door is open, at least 2 foot-candles of illumination measured on the step tread, ramp, bridge plate...
-
Passenger Loading Zones
to provide passenger loading zones, and urged a revision that would require one accessible passenger loading zone located in reasonable proximity to each building entrance served by the curb...
-
608.1 General
Shower stalls that are 60 inches (1525 mm) wide and have no curb may increase the usability of a bathroom because the shower area provides additional maneuvering space....
-
Surface discontinuities
Elevation changes due to ramps or stairs do not, themselves, constitute surface discontinuities....