The technical requirements address the clear ground space (1015.2) and viewing space (1015.3) at distinct viewing locations; the turning space within viewing areas (1015.4); and the surface...
Search Results "Clear Opening"
Commonly Searched Documents
-
1015.1 General
-
4.5.1 General
In alterations, where a condition for exception in section 1.1 prohibits full compliance with a specific requirement for clear floor or ground space surface, slope, size, or location, the...
-
810.2.2 Dimensions--Modification to 810.2.2 of Appendix D to 36 CFR Part 1191
810.2.2 Dimensions--Modification to 810.2.2 of Appendix D to 36 CFR Part 1191 Bus boarding and alighting areas shall provide a clear length of 96 inches (2440 mm), measured perpendicular...
- Seton Economy Braille Signs - Men's Restroom with ISA
- Seton Economy Braille Signs - Women's Restroom with ISA
-
1134A.8, Item 4.1
The space beneath the lavatory shall be left clear and unobstructed;...
-
1011.2.2 Surface
This section requires the surface of the clear ground space to be firm and stable....
-
1134A.8, Item 4.1
The space beneath the lavatory shall be left clear and unobstructed;...
-
LULA Elevator Dimensions
The guidelines specify that LULA elevator cars be at least 42 inches wide and 54 inches deep with a door on the narrow end providing at least 32 inches clear width (408.4.1)....
-
304.3.2 T-Shaped Space
Each arm of the T shall be clear of obstructions 12 inches (305 mm) minimum in each direction and the base shall be clear of obstructions 24 inches (610 mm) minimum....
-
M9
[ADA Standards § 4.19.2] Yes No Notes: 1. 48-inch minimum by 66-inch minimum clear floor space for toilet 2. 48-inch minimum by 30-inch minimum clear floor space...
-
304.3.2 T-Shaped Space
Each arm of the T shall be clear of obstructions 12 inches (305 mm) minimum in each direction and the base shall be clear of obstructions 24 inches (610 mm) minimum....
-
304.3.2 T-Shaped Space
Each arm of the T shall be clear of obstructions 12 inches (305 mm) minimum in each direction and the base shall be clear of obstructions 24 inches (610 mm) minimum....
-
1015.3 Viewing Space
This section requires each distinct viewing location to provide a viewing space adjacent to the clear ground space required by 1015.2 through which the point of interest is viewable....
-
1133A.7 Knee and toe space
Knee and toe space, when required by Section 1133A, shall comply with Section 1138A.2 and the following: The knee and toe space shall be clear and unobstructed, or removable base cabinets...
-
R210 Protruding Objects
Objects along or overhanging any portion of a pedestrian circulation path shall comply with R402 and shall not reduce the clear width required for pedestrian access routes....
- Activar JL Industries 1900 Series Dual AED & Emergency Oxygen Recessed or Surface-Mounted Cabinet
- Tenon LLC
-
404.2.7 Door and Gate Hardware
Where sliding doors are in the fully open position, operating hardware shall be exposed and usable from both sides....
-
404.2.7 Door and Gate Hardware
Where sliding doors are in the fully open position, operating hardware shall be exposed and usable from both sides....
-
A4.13.9 DOOR HARDWARE
Some disabled persons must push against a door with their chair or walker to open it....
-
Maneuvering Clearances [§404.2.4]
Maneuvering Clearances [§404.2.4] Required maneuvering clearances provide space for opening and proceeding through doors, doorways, and gates using wheelchairs and other mobility aids...
-
1133A.6 Kitchen sink faucet controls
Self-closing valves are allowed if the faucet remains open for at least 10 seconds....
-
11B-604.7.2 Disposal units
The disposal unit shall be located below the grab bar with the opening of the disposal unit 19 inches minimum (483 mm) above the finish floor....