Visual display shall provide contrast with light characters on a dark background or dark characters on a light background. The background shall be solid and static....
Search Results "Visual Alarm"
-
11B-411.4.11.2 Contrast
-
F215 Fire Alarm Systems
[See subsections ...]
-
215 Fire Alarm Systems
[See subsections ...]
-
In Your Guest Room:
If they are locked, report it right away. 1.2 Find the nearest fire alarm. Generally, it is located near the exit or stairwell door or elevators....
-
Two-way Communication [4.3.11.4]
The two-way communication system must be equipped with both audible signals (for people with vision impairments) and visual signals (for people with hearing impairments) and cannot operate...
-
203 General Exceptions
New: Requirements for common use circulation (206.2.8); means of egress (207.1); visual alarm connection (215.3)...
-
§1193.43(a) Availability of visual information
(a) Availability of visual information. Provide visual information through at least one mode in auditory form....
-
11B-702 FIRE ALARM SYSTEMS
[See subsections ...]
-
11B-702 Fire alarm systems
[See subsections ...]
-
907.2.10.1 Where required
Single-or multiple-station smoke alarms shall be installed in the locations described in Sections 907.2.10.1.1 through 907.2.10.1.4....
- Carbon Monoxide Alarm Transmitter (BE1210)
-
SECTION 907 FIRE ALARM AND DETECTION SYSTEMS
[See subsections ...]
-
SECTION 907 FIRE ALARM AND DETECTION SYSTEMS
[See subsections ...]
-
11B-809.5.2.1 Activation
All visible alarm appliances provided within the residential dwelling unit for smoke detection notification shall be activated upon smoke detection....
-
11B-809.5.2.1 Activation
All visible alarm appliances provided within the residential dwelling unit for smoke detection notification shall be activated upon smoke detection....
- Plantronics Clarity XLC2 Phone
- Safety Technology International Mini Theft Stopper
-
[F] 907.4.2.2 Height
The height of the manual fire alarm boxes shall be not less than 42 inches (1067 mm) and not more than 48 inches (1219 mm) measured vertically, from the floor level to the highest point...
-
[F] 907.4.2.2 Height
The height of the manual fire alarm boxes shall be not less than 42 inches (1067 mm) and not more than 48 inches (1219 mm) measured vertically, from the floor level to the highest point...
-
11B-703.5.10 Format
Text shall be in a horizontal format.
-
11B-703.5.10 Format
Text shall be in a horizontal format.
-
Cells with Communication Features: ADA Standard Section 232.2.2
Section 232.2.2 covers scoping requirements in the current ADA Standards for cells with communication features.
-
11B-232.2.2 Cells with communication features
At least 2 percent, but no fewer than one, of the total number of general holding cells and general housing cells equipped with audible emergency alarm systems and permanently installed...
-
11B-232.2.2 Cells with communication features
At least 2 percent, but no fewer than one, of the total number of general holding cells and general housing cells equipped with audible emergency alarm systems and permanently installed...