Raised characters shall comply with 703.2 and shall be duplicated in braille complying with 703.3. Raised characters shall be installed in accordance with 703.4....
Search Results "Uppercase Character (Visual)"
Commonly Searched Documents
-
703.2 Raised Characters
-
Emergency Communication: ADA Standard Section 407.4.9
Section 407.4.9: covers the current ADA Standards for the elevator emergency communication systems.
-
11B-216.2 Designations
People with visual impairments benefit from tactile signs containing raised characters and/or symbols and accompanying Braille....
-
703.2.6 Stroke Thickness
Stroke thickness of the uppercase letter “I” shall be 15 percent maximum of the height of the character....
-
11B-703.5.3 Style
Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms. [S.H. ...
-
11B-407.2.3.1 Floor designation
Floor designations shall be provided in both raised characters and Braille. Raised characters shall be 2 inches (51 mm) high....
-
703.5.6 Height from Finish Floor or Ground
Visual characters shall be 40 inches (1015 mm) minimum above the finish floor or ground....
-
703.5.6 Height From Finish Floor or Ground
Visual characters shall be 40 inches (1015 mm) minimum above the finish floor or ground....
-
§1193.43(b) Availability of visual information for low vision users
(b) Availability of visual information for low vision users....
-
Raised and Braille Characters on Hoistway Entrances [4.10.5]
Raised characters must be 2 inches high. Braille characters are often located below raised characters, although the location is not specified in ADAAG....
-
703.5.6 Height from Finish Floor or Ground
Visual characters shall be 40 inches (1015 mm) minimum above the finish floor or ground....
-
11B-216.4.3 Directional signs
Signs required by Chapter 10, Section 1007.10 to provide directions to accessible means of egress shall comply with Section 11B-703.5 _|Signs; Visual Characters|_. ...
-
11B-216.4.3 Directional signs
Signs required by Chapter 10, Section 1009.10 to provide directions to accessible means of egress shall comply with Section 11B-703.5 _|Signs; Visual Characters|_....
-
Floor Designation: ADA Standard Section 407.2.3.1
Section 407.2.3.1 covers the current ADA Standards for elevator floor designations.
-
11B-703.2 Raised characters
11B-703.2 Raised characters. Raised characters shall comply with Section 11B-703.2 and shall be duplicated in Braille complying with Section 11B-703.3....
-
Paragraph (a) Availability of visual information (Section-by-Section Analysis)
Paragraph (a) Availability of visual information (Section-by-Section Analysis) No substantive comments were received on this paragraph and no changes were made, other than the editorial...
-
F216.4.1 Exit Doors
Doors at exit passageways, exit discharge, and exit stairways shall be identified by tactile signs complying with 703.1, 703.2, and 703.5. Advisory F216.4.1 Exit Doors. An exit...
-
216.4.1 Exit Doors
Doors at exit passageways, exit discharge, and exit stairways shall be identified by tactile signs complying with 703.1, 703.2, and 703.5. Advisory 216.4.1 Exit Doors. An exit...
-
216.4.1 Exit Doors
216.4.1 Exit Doors. Doors at exit passageways, exit discharge, and exit stairways shall be identified by tactile signs complying with 703.1, 703.2, and 703.5. Advisory 216.4.1...
-
11B-216.4.1 Exit doors
Signs required by Chapter 10, Section 1013.4 at doors to exit passageways, exit discharge, and exit stairways shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and...
-
907.5.2.3 Visible alarms
Visual alarm notification appliances are not required in critical care areas of Group I-2 occupancies that are in compliance with Section 907.5.2.5....
-
11B-703.2 Raised characters
Raised characters shall comply with Section 11B-703.2 and shall be duplicated in Braille complying with Section 11B-703.3....
-
11B-703.2 Raised characters
Raised characters shall comply with Section 11B-703.2 and shall be duplicated in Braille complying with Section 11B-703.3....
-
Visual Devices for the Fire Alarm System
Many codes require new buildings to have flashing strobe lights (visual devices) as part of the standard building alarm system, but because the requirements are not retroactive many buildings...