At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing....
Search Results "Pool Stair"
Commonly Searched Documents
-
11B-505.10.2 Top extension at stairs
- Figure 1009.2.3 Clear Deck Space at Pool Lifts – Drawing from the U.S. Access Board
-
Technical Memorandum TM 2012-06 Wading Pools
TM 2012-06 Wading Pools Effective Date: January 22, 2013 2012 TAS Reference: 242.3 The 2012 TAS does not provide a specific definition of a wading pool and neither does the...
-
Seat Height
Seat Height The lift must be designed so that the seat will make a stop between a minimum of 16 inches and maximum of 19 inches (measured from the deck to the top of the seat...
-
Submerged Depth
Submerged Depth Lifts must be designed so that the seat will submerge to a minimum of 18 inches below the stationary water level. This will ensure buoyancy for the person on the...
-
Lifting Capacity
Lifting Capacity Lifts must have the capability of supporting a minimum weight of 300 pounds and be capable of sustaining a static load that is at least 1.5 times the rated load....
-
Are exterior stairs required to comply with the Standards?
The Standards apply to both exterior and interior stairs that are part of a required means of egress....
-
11B-505.10.2 Top extension at stairs
At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing....
-
11B-505.10.2 Top extension at stairs
At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing....
-
1011.11 Handrails
... [DSA-AC] For applications listed in Section 1.9.1 regulated by the Division of the State Architect-Access Compliance, see Chapter 11B, Sections 11B-504.6 and 11B-505.
-
11B-505.2.1 Orientation
The orientation of at least one handrail shall be in the direction of the stair run, perpendicular to the direction of the stair nosing, and shall not reduce the minimum required width of...
-
11B-505.2.1 Orientation
The orientation of at least one handrail shall be in the direction of the stair run, perpendicular to the direction of the stair nosing, and shall not reduce the minimum required width of...
-
Stairs, short-term list
I’ll put one up there, short-term, stairs....
-
OTHER QUESTIONS
[See subsections ...]
-
504.5 Nosings
The radius of curvature at the leading edge of the tread shall be 1/2 inch (13 mm) maximum. Nosings that project beyond risers shall have the underside of the leading edge curved or...
-
4.9.3 Nosings
The undersides of nosings shall not be abrupt. The radius of curvature at the leading edge of the tread shall be no greater than 1/2 in (13 mm). Risers shall be sloped or the...
-
4.9.3 NOSINGS
The undersides of nosings shall not be abrupt. The radius of curvature at the leading edge of the tread shall be no greater than 1/2 in (13 mm). Risers shall be sloped or the...
-
S.R. Smith PAL2 Pool Lift Video: Maintenance
Requires the Registered User plan or above. Login!
- Aqua Creek Scout Excel
- Figure 505.10.3 Bottom Handrail Extension at Stairs – Drawing from the U.S. Access Board
- Figure 505.10.2 Top Handrail Extension at Stairs – Drawing from the U.S. Access Board
-
General: ADA Standard Section 505.1
Section 505.1 of the ADA Standards covers information in the current ADA Standards for handrails.
-
11B-505.1 General
Handrails provided along walking surfaces complying with Section 11B-403, required at ramps complying with Section 11B-405, and required at stairs complying with Section 11B-504 shall comply...
-
New Construction
New Construction The 2010 Standards, which set requirements for fixed elements and spaces, require that all new pool facilities built by State and local governments, public accommodations...