Search Results "Mammography Chair"
Commonly Searched Documents
- Amos Winter: The cheap all-terrain wheelchair | TED Talks
-
4.4.3 Implications of Mammography Equipment Components
4.4.3 Implications of Mammography Equipment Components To determine the accessibility standard recommendations, understanding mammography equipment components is essential....
-
M305.3.1 Length
The length of gripping surfaces for standing supports shall be based on the position of the standing supports in relation to the standing surfaces they serve. Horizontal standing...
-
M305.3.1 Length (Section-by-Section Analysis)
In the MDE NPRM, the Access Board proposed a gripping surface length of four inches minimum for horizontal standing supports. No public comments were submitted on this requirement....
-
4.4.1 Overview of Mammography Accessibility Considerations
4.4.1 Overview of Mammography Accessibility Considerations Mammography equipment will likely require redesign to fully accommodate women seated in wheelchairs....
-
Checklist for Inclusive Emergency Safety Briefings for Attendees
accessible exit pathways emergency meeting areas outside the facility evacuation devices are fold‑up chairs...
- Brewer Access™ High-Low Exam Table
-
PART 3: ACCESSIBLE EXAMINATION ROOMS
An accessible examination room has features that make it possible for patients with mobility disabilities, including those who use wheelchairs, to receive appropriate medical care....
-
M302.4 Lift Compatibility
Diagnostic equipment shall be usable with portable patient lifts and, when in use with such lifts, shall comply with M302.4.1 or M302.4.2. EXCEPTION: Where fixed overhead patient...
-
M302.4 Lift Compatibility (Section-by-Section Analysis)
The MDE NPRM proposed to require that diagnostic equipment used by patients in the seated position be usable with a patient lift and comply with either the proposed clearance in base...
-
Figure M2: M301.4 Lift Compatibility
(at Diagnostic Equipment for Use by a Patient in a Supine, Prone, or Side-Lying Position)
-
M302.4 Lift Compatibility
Diagnostic equipment shall be usable with a patient lift and shall comply with M302.4.1 or M302.4.2. EXCEPTION: Where diagnostic equipment meets the requirements of M303 and...
- Brewer Access™ High-Low Exam Table 700
-
Portable Floor Lifts
Portable Floor Lifts The most common types of lifts in medical settings are portable with a U-shaped base that moves along the floor on wheels. These bases must go under, or fit...
-
M101.2 Application (Section-by-Section Analysis)
The first is to exempt examination chairs which comply with M302 and can be reclined to facilitate diagnosis after the patient transfers onto the seat from complying with M301....
-
M301.4.1 Clearance in Base
[See subsections ...]
-
M305.2.8 Fittings (Section-by-Section Analysis)
An accessibility consultant recommended swing-away or removable armrests for chairs to allow for transfer on either side....
-
Accessible Medical Equipment
Importance of Accessible Examination Tables, Chairs and Weight Scales http://www.hfcdihp.org/products Exam Room Selection for Accessible Examination Tables & Chairs PDF , Word...
-
Clear Floor and Turning Space Inside Examination Rooms
Movable chairs and other objects, such as waste baskets, should be moved aside if necessary to provide sufficient clear floor space for maneuvering and turning....
-
Additional Transfer Techniques: Use of Stretchers and Gurneys
Additional Transfer Techniques: Use of Stretchers and Gurneys Some equipment, including radiologic equipment, lacks space underneath necessary for a portable floor lift to be...
-
Transfer Supports Location and Configuration M301.3 and M302.3
Transfer Supports Location and Configuration M301.3 and M302.3 Location of the transfer supports shall be a minimum of 6 inches to a maximum of 19 inches from the top of the...
-
Gripping Surface Cross Section and Clearances M301, M302, and M305.2
Gripping Surface Cross Section and Clearances M301, M302, and M305.2 Gripping surface for transfer supports shall be free of sharp or abrasive elements and shall have rounded...
-
Determine All Your Evacuation Options and Prioritize Them
wheelchair) Pros Cons You have a chance to GET OUT You and/or your helpers may be injured in the process Use of Evacuation Chairs...
-
5.1 Transfer Surface Height Recommendations
This height is also critical for patients who use mobility aids such as walkers and canes and may find it difficult to get up onto or down from an examination chair or table or imaging bed...