A visible and audible signal shall be provided at each hoistway entrance to indicate which car is answering a call and the car's direction of travel....
Search Results "Hall Call Console"
-
407.2.2.1 Visible and Audible Signals
-
407.2.2.1 Visible and Audible Signals
A visible and audible signal shall be provided at each hoistway entrance to indicate which car is answering a call and the car's direction of travel....
-
11B-604.5.1 Side wall
The side wall grab bar shall be 42 inches (1067 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1372 mm) minimum from the rear wall...
-
11B-604.5.1 Side wall
The side wall grab bar shall be 42 inches (1067 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1372 mm) minimum from the rear wall...
-
4.10.4(2)
(2) Visual elements shall be at least 2‒1/2 in (64 mm) in the smallest dimension.
- ADA-100® Area of Refuge Communication System
- Viking K-1600-EHFA Elevator Phone with Built-in Dialer and Digital Announcer
-
Relationship Between Primary and Secondary PSAPs
Primary PSAPs (9-1-1 answering points) often transfer calls to secondary PSAPs (such as fire or emergency medical services) if they do not dispatch those services directly from the primary...
-
407.2.2.3 Audible Signals
The audible signal and verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the hall call button. EXCEPTIONS: 1....
-
407.2.2.3 Audible Signals
The audible signal and verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the hall call button. EXCEPTIONS: 1....
-
407.2.2.3 Audible Signals
The audible signal and verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the hall call button. EXCEPTIONS: 1....
-
11B-407.2.2.3 Audible signals
The audible signal and verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the hall call button. Exceptions: 1. ...
-
11B-407.2.2.3 Audible signals
The audible signal and verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the hall call button. Exceptions: 1. Reserved. 2....
-
11B-407.2.2.3 Audible signals
The audible signal and verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the hall call button. Exceptions: Reserved. Reserved....
- Viking E-1600-02A-EWP Emergency Phones with Built-in Auto Dialer and Digital Announcer with Weather Protection
- Viking E-1600A Elevator Phones with Built-in Digital Announcers
- Viking E-1600-02A Emergency Phone with Built-in Auto Dialer and Digital Announcer
- Viking Talk-A-Phones ETP-400V and ETP-400DV, Panel Phone E-1600A-TP-EWP
- Viking E-1600-55A Emergency Phones with Built-in Auto Dialer and Digital Announcer
- Allen Tel ADA Outdoor Phone with Amplified Receiver and No Dial - No Housing
- Allen Tel ADA Outdoor Disability Speakerphone Single Number Dial
- Allen Tel Emergency Phone Automatic Ring Down - No Dial
- Allen Tel Emergency Phone Automatic Ring Down Circuit - Single Number Dial
- Allen Tel ADA Outdoor Phone with Amplified Receiver and No Dial