407.2.2.1 Visible and Audible Signals
-
407.2.2.1 Visible and Audible Signals
A visible and audible signal shall be provided at each hoistway entrance to indicate which car is answering a call and the car's direction of travel....
-
11B-805.7 Built-in cabinets and work surfaces
work surfaces shall be accessible, including: patient wardrobes, nurse’s stations, administrative centers, reception desks, medicine preparation areas, laboratory work stations, equipment consoles...
- Viking E-1600-20A Emergency Phones with Built-in Auto Dialer and Digital Announcer
- Viking E-1600-03B Emergency Phones with Built-in Auto Dialer and Digital Announcer
- Viking E-1600-03B-EWP Emergency Phones with Built-in Auto Dialer and Digital Announcer with Weather Protection
-
407.2.2.1 Visible and Audible Signals
A visible and audible signal shall be provided at each hoistway entrance to indicate which car is answering a call and the car's direction of travel....
- Viking E-1600A-BLT-EWP Emergency Tower Phone with Blue LED Beacon and Strobe Light
- Viking E-1600-45A-EWP Emergency Phones with Built-in Auto Dialer and Digital Announcer with Weather Protection
- Viking E-1600A-BLT2EWP Emergency Tower Phone with Blue Strobe Light, Voice Announcer and Weather Protection
-
11B-604.5.1 Side wall
The side wall grab bar shall be 42 inches (1067 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1372 mm) minimum from the rear wall...
-
4.10.4(2)
(2) Visual elements shall be at least 2‒1/2 in (64 mm) in the smallest dimension.
- Viking E-1600-IP VoIP Emergency Phones with Built-in Auto Dialer and Digital Announcer
-
11B-407.2.2.3 Audible signals
The audible signal and verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the hall call button. Exceptions: 1. ...
-
11B-407.2.2.3 Audible signals
The audible signal and verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the hall call button. Exceptions: 1. Reserved. 2....
-
11B-407.2.2.3 Audible signals
The audible signal and verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the hall call button. Exceptions: Reserved. Reserved....
-
407.2.2.3 Audible Signals
The audible signal and verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the hall call button. EXCEPTIONS: 1....
-
407.2.2.3 Audible Signals
The audible signal and verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the hall call button. EXCEPTIONS: 1....
-
407.2.2.3 Audible Signals
The audible signal and verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the hall call button. EXCEPTIONS: 1....
-
Relationship Between Primary and Secondary PSAPs
Primary PSAPs (9-1-1 answering points) often transfer calls to secondary PSAPs (such as fire or emergency medical services) if they do not dispatch those services directly from the primary...
-
Can audible signals for an elevator operate only when needed by a passenger who needs them through activation of dedicated “accessibility” control?
No, audible (and visible) signals required for elevators must function automatically at all times an elevator is operational. Requiring passengers to manually activate such signals...