In standard stalls, the front partition and at least one side partition shall provide a toe clearance of at least 9 in (230 mm) above the floor. If the depth of the stall is greater...
Search Results "End of Row Compartment"
Commonly Searched Documents
-
4.17.4 Toe Clearances
-
4.21 Shower Stalls
[See subsections ...]
-
A4.21 Shower Stalls
[See subsections ...]
-
4.17.4 TOE CLEARANCES
In standard stalls, the front partition and at least one side partition shall provide a toe clearance of at least 9 in (230 mm) above the floor. If the depth of the stall is greater...
-
4.21.1* GENERAL
Accessible shower stalls shall comply with 4.21. For shower stalls in accessible dwelling units, see 4.34.5.5.
-
A4.21 SHOWER STALLS
[See subsections ...]
-
Shower Stalls (ADAAG 4.21)
Shower Stalls (ADAAG 4.21) Although ADAAG permits both transfer and a roll-in showers, roll-in showers were found in institutional facilities. As a result, design of shower stalls...
-
11B-608.10 Soap dish
11B-608.10 Soap dish. Where a soap dish is provided, it shall be located on the control wall at 40 inches (1016 mm) maximum above the shower floor, and within the reach limits from...
-
11B-608.10 Soap dish
Where a soap dish is provided, it shall be located on the control wall at 40 inches (1016 mm) maximum above the shower floor, and within the reach limits from the seat.
-
213 Toilet Facilities and Bathing Facilities
If water closets are not in stalls, then at least one shall comply with 4.16. 213.3.1 Toilet Compartments....
-
11B-213.3.6 Bathing facilities
Transfer type shower compartments shall be permitted in transient lodging guest rooms, multi-bedroom housing units in undergraduate student housing and residential dwelling units; and shall...
-
11B-604.8.1.1.1 Maneuvering space with in-swinging door
In a wheelchair accessible compartment with an in-swinging door, a minimum 60 inches (1524 mm) wide by 36 inches (914 mm) deep maneuvering space shall be provided in front of the clearance...
-
11B-604.8.1.1.1 Maneuvering space with in-swinging door
In a wheelchair accessible compartment with an in-swinging door, a minimum 60 inches (1524 mm) wide by 36 inches (914 mm) deep maneuvering space shall be provided in front of the clearance...
-
M301.2.3.1 End Transfer Surface
End transfer surfaces shall be 28 inches (710 mm) wide minimum and 17 inches (430 mm) long minimum. ...
-
§ 38.127(b)
(b) Each accessible compartment shall contain a restroom complying with §38.123(a) which can be entered directly from such compartment....
-
11B-604.8.1.1.1 Maneuvering space with in-swinging door
In a wheelchair accessible compartment with an in-swinging door, a minimum 60 inches (1524 mm) wide by 36 inches (914 mm) deep maneuvering space shall be provided in front of the clearance...
-
11B-809.10.6.5 Thresholds
Where provided thresholds shall be 2 inches (51 mm) maximum in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from the...
- Hadrian Inc. Powder Coated Toilet Partition
-
C. Toilet Rooms:
PSE shall provide at least nine (9) 60-inch wide accessible toilet compartments, located in multi-user toilet rooms, and at least six (6) accessible water closets with 60-inch wide...
-
604.8.1.6 Lavatory
In new construction, the wheelchair accessible toilet compartment shall contain an accessible lavatory within it, which must be at least 19 inches wide by 17 inches deep, nominal size, and...