Section 206.5.3 covers scoping requirements in the most current ADA Standards for accessible routes to transient lodging facilities.
Search Results "Door Closer"
Commonly Searched Documents
-
Transient Lodging Facilities: ADA Standard Section 206.5.3
-
404.2.4.1 Swinging Doors and Gates
Table 404.2.4.1 Maneuvering Clearances at Manual Swinging Doors and Gates Type of Use Minimum Maneuvering Clearance Approach Direction Door or Gate Side...
- SafeZone: Norton Factory Video 7 22 14
-
Duration: ADA Standard Section 407.3.3.3
Section 407.3.3.3 covers the current ADA Standards for the duration of an elevators reopening device.
-
11B-407.3.3.3 Duration
Door reopening devices shall remain effective for 20 seconds minimum....
-
A4.13.11(2) Sliding or folding doors
(2) Sliding or folding doors: Force applied parallel to the door at the door pull or latch....
-
A4.13.11(2) Sliding or folding doors
(2) Sliding or folding doors: Force applied parallel to the door at the door pull or latch....
-
A4.13.12 Automatic Doors and Power-Assisted Doors
Sliding automatic doors do not need guard rails and are more convenient for wheelchair users and visually impaired people to use....
-
A4.13.12 AUTOMATIC DOORS AND POWER-ASSISTED DOORS
Sliding automatic doors do not need guard rails and are more convenient for wheelchair users and visually impaired people to use....
-
Contact: ADA Standard Section 407.3.3.2
Section 407.3.3.2 covers the current ADA Standards for the contact requirements of an elevators reopening device.
-
11B-407.3.3.2 Contact
The device shall not require physical contact to be activated, although contact is permitted to occur before the door reverses....
- Besam PowerSwing Electro-hydraulic Swing Door Operator
-
Entry Doors
Entry Doors Under the ADA Standards for Accessible Design, an accessible doorway must have a minimum clear opening width of 32 inches when the door is opened to 90 degrees....
-
404.2.4.1 Swinging Doors and Gates
Swinging doors and gates shall have maneuvering clearances complying with Table 404.2.4.1....
- DORMA ED700 Low-Energy Swing Door Operator
-
11B-206.5.1 Entrances
Each entrance to a building or facility required to comply with 206.4 shall have at least one door, doorway, or gate complying with 404....
-
Reopening Device: ADA Standard Section 407.3.3
Section 407.3.3 covers the current ADA Standards for elevator reopening devices.
-
11B-407.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-407.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
-
1132A.6 Closer-effort to operate doors
Maximum effort to operate doors shall not exceed 8½ pounds (38 N) for exterior doors and 5 pounds (22 N) for interior doors, such pull or push effort being applied at right angles to hinged...
-
1132A.6 Closer-effort to operate doors
Maximum effort to operate doors shall not exceed 8½ pounds (38 N) for exterior doors and 5 pounds (22 N) for interior doors, such pull or push effort being applied at right angles to hinged...
-
404.3.4 Doors in Series and Gates in Series
404.3.4 Doors in Series and Gates in Series. Doors in series and gates in series shall comply with 404.2.6....
- Besam PowerSwing Electro-hydraulic Swing Door Operator BIM
-
Toilet Room Doors
Other commenters asserted that public single-user toilet rooms always include a closer and a latch on the entry door, requiring a larger clear floor space than shown on the push side of...
-
11B-407.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....