Cross Slope. ...
Search Results "Counter Slope"
Commonly Searched Documents
-
Cross Slope
-
106.5.56 Running Slope
The slope that is parallel to the direction of travel (see cross slope)....
-
106.5.22 Cross Slope
The slope that is perpendicular to the direction of travel (see running slope)....
-
11B-231.4.1 Cubicles and counters
Where counters are provided, at least one shall comply with Section 11B-904.4.2 on both the visitor and detainee sides....
-
B. Slopes
Slopes - Examine each of the interior routes described above: ...excluding accessible ramps, do the corridors have running slopes (i.e.: in the direction of travel) not more than 1:20...
-
11B-231.4.1 Cubicles and counters
Where counters are provided, at least one shall comply with Section 11B-904.4.2 _|Forward Approach|_ on both the visitor and detainee sides....
-
11B-231.4.1 Cubicles and counters
Where counters are provided, at least one shall comply with Section 11B-904.4.2 _|Forward Approach|_ on both the visitor and detainee sides....
-
Museum Gift Shop
The 42" height of the main cashier counter and the 42 1/2" height of the second cashier counter exceed the maximum 36" allowable height above the finished floor....
-
F227.1 General
Where provided, check-out aisles, sales counters, service counters, food service lines, queues, and waiting lines shall comply with F227 and 904....
-
227.1 General
Where provided, check-out aisles, sales counters, service counters, food service lines, queues, and waiting lines shall comply with 227 and 904....
-
11B-227.1 General
Where provided, check-out aisles, sales counters, service counters, food service lines, queues, and waiting lines shall comply with Sections 11B-227 and 11B-904....
-
11B-227.1 General
Where provided, check-out aisles, sales counters, service counters, food service lines, queues, and waiting lines shall comply with Sections 11B-227 and 11B-904....
-
11B-227.1 General
Where provided, check-out aisles, sales counters, service counters, food service lines, queues, and waiting lines shall comply with Sections 11B-227 and 11B-904....
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain....
-
Slope [1013.3]
When the surface is constructed of materials other than asphalt, concrete, or boards, slopes no steeper than 1:20 (5 percent) are allowed when necessary for drainage....
-
227.1 General
Where provided, check-out aisles, sales counters, service counters, food service lines, queues, and waiting lines shall comply with 227 and 904....
-
1016.8.3 Slope
This section requires the slope of resting intervals to not be steeper than 1:48 in any direction....
-
1016.8.3 Slope
Resting intervals shall have slopes not steeper than 1:48 in any direction....
-
1016.8.3 Slope
Resting intervals shall have slopes not steeper than 1:48 in any direction....
-
1016.7.2 Cross Slope
The cross slope shall not be steeper than 1:48....
-
2.4.2 Cross Slope
The cross slope of an ORAR shall be no more than 1:33 (3 percent)....
-
1016.7.2 Cross Slope
The cross slope shall not be steeper than 1:48....
-
1014.2.1.1.2 Slope
The slope of the surface of the clear ground space shall not be steeper than 1:48 in any direction....