404.3 Automatic and Power-Assisted Doors and Gates
Full-powered automatic doors shall comply with ANSI/BHMA A156.10 (incorporated by reference, see "Referenced Standards" in Chapter 1)....
-
Cross Slope [1016.7.2]
When the surface is constructed of concrete, asphalt, or boards, the cross slope must be no steeper than 1:48 (2 percent)....
-
404.3 Automatic and Power-Assisted Doors and Gates
Full-powered automatic doors shall comply with ANSI/BHMA A156.10 (incorporated by reference, see "Referenced Standards" in Chapter 1)....
-
12204(c)(2) Sites eligible for listing in National Register
.), the guidelines described in paragraph (1) shall, at a minimum, maintain the procedures and requirements established in 4.1.7(1) and (2) of the Uniform Federal Accessibility Standards...
-
407.12.1.1 Vertical Plane for Side Reach (Section-by-Section Analysis)
This side reach requirement mirrors existing 508 Standards § 1194.25(j)(1) and Figure 1....
-
1008.1.9.7, Item 5
THIS DOOR WILL OPEN IN 15 [30] SECONDS ALARM WILL SOUND” Sign lettering shall be at least 1 inch (25 mm) in height and shall have a stroke of not less than 1/8 inch (3.2 mm)....
-
68.20. Buildings and Facilities Subject to Compliance with the Texas Accessibility Standards
Buildings and Facilities Subject to Compliance with the Texas Accessibility Standards (New rule section effective November 5, 2001, 26 TexReg 8807; amended effective February 1, 2005, 30...
-
11B-407.4.6.2.1 Size and shape
Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding surface...
-
Slopes and Resting Intervals for Outdoor Recreation Access Routes
Runnign [sic] Slopes on ORARs Maximum Length of Segment Between Resting Intervals Steeper than But not Steeper than 1:20 (5 percent) 1:12 (8.33...
-
505.1 General
Handrails are not required on walking surfaces with running slopes less than 1:20....
-
505.1 General
Handrails are not required on walking surfaces with running slopes less than 1:20....
-
B. Communication Rooms
[ADA Stds. 9.1.3] (Table 9.1.3) Number of Rooms In the Hotel Rooms for Hearing Impaired Guests 1 - 25 1 26...
-
11B-505.1 General
Handrails are not required on walking surfaces with running slopes less than 1:20....
-
Gangway Slope and Rise Exceptions
As a minimum however, gangways must be designed to provide for a maximum 1:12 (8.33%) slope but are not required to be longer than 80 feet in length....
-
3104.2 Separate structures
Exceptions: 1. Buildings on the same lot in accordance with Section 503.1.2 shall be considered a single structure. 2. ...
-
404.2.5 Thresholds
Thresholds, if provided at doorways, shall be 1/2 inch (13 mm) high maximum. Raised thresholds and changes in level at doorways shall comply with 302 and 303....
-
404.2.5 Thresholds
Thresholds, if provided at doorways, shall be 1/2 inch (13 mm) high maximum. Raised thresholds and changes in level at doorways shall comply with 302 and 303....
-
410.6.3.1 PSTN (Section-by-Section Analysis)
with real-time two-way voice communication interoperates with the publicly switched telephone network (PSTN), real-time text conform to TIA 825-A (incorporated by reference in 508 Chapter 1...
-
4.10.9 Floor Plan of Elevator Cars
The clearance between the car platform sill and the edge of any hoistway landing shall be no greater than 1‒1/4 in (32 mm)....
-
4.10.9 FLOOR PLAN OF ELEVATOR CARS
The clearance between the car platform sill and the edge of any hoistway landing shall be no greater than 1-1/4 in (32 mm)....
-
11B-407.4.6.2.1 Size and shape
Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding surface...