Passenger drop-off and loading zones shall provide access aisles complying with Section 11B-503 adjacent and parallel to the vehicle pull-up space....
Search Results "Shall"
Commonly Searched Documents
-
11B-503.3 Access aisle
-
303.1 General
Where changes in level are permitted in floor or ground surfaces, they shall comply with 303. EXCEPTIONS: 1. Animal containment areas shall not be required to comply with 303. 2....
-
407.3 Tactilely Discernible
At least one tactilely discernible input control shall be provided for each function and shall conform to 407.3....
-
11B-503.3 Access aisle
Passenger drop-off and loading zones shall provide access aisles complying with Section 11B-503 adjacent and parallel to the vehicle pull-up space....
-
1134A.6, Item 2
The maximum slope of the shower floor shall be ½ inch (12.7 mm) per foot in any direction and shall slope to a drain....
-
11B-707.5.1 User control
Speech shall be capable of being repeated or interrupted. Volume control shall be provided for the speech function....
-
1009.7.3 Openness
The exterior area for assisted rescue shall be open to the outside air....
-
1009.7.3 Openness
The exterior area for assisted rescue shall be open to the outside air....
-
11B-812.3 Floor or ground surfaces
Vehicle spaces and access aisles serving them shall comply with Section 11B-302. Access aisles shall be at the same level as the vehicle space they serve....
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain....
-
11B-607.5 Controls
Controls, other than drain stoppers, shall be located on an end wall....
-
11B-608.9 Shower floor or ground surface
Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction....
-
11B-503.3 Access aisle
Passenger drop-off and loading zones shall provide access aisles complying with Section 11B-503 adjacent and parallel to the vehicle pull-up space....
-
11B-307.4 Vertical clearance
Vertical clearance shall be 80 inches (2032 mm) high minimum. Guardrails or other barriers shall be provided where the vertical clearance is less than 80 inches (2032 mm) high....
-
903.4 Back Support
The bench shall provide for back support or shall be affixed to a wall....
-
4. Purpose of Settlement
of protracted litigation and preclude any similar lawsuits or challenges during the Compliance Period, the City and Plaintiffs agree to enter into this Settlement Agreement and that it shall...
-
5.1* General
Except as specified or modified in this section, restaurants and cafeterias shall comply with the requirements of 4.1 to 4.35....
-
11B-307.4 Vertical clearance
Vertical clearance shall be 80 inches (2032 mm) high minimum. Guardrails or other barriers shall be provided where the vertical clearance is less than 80 inches (2032 mm) high....
-
11B-603.4 Coat hooks, shelves and medicine cabinets
Coat hooks shall be located within one of the reach ranges specified in Section 11B-308....
-
11B-803.5 Coat hooks and shelves
Coat hooks provided within the room shall be located within one of the reach ranges specified in Section 11B-308....
-
11B-809.10.5.1 Clear floor space
A clear floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be located with the long edge of the clear floor space parallel to the side of the bathtub or bathtub-shower...
-
11B-604.5.2 Rear wall
The rear wall grab bar shall be 36 inches (914 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on...
-
Slope: ADA Standard Section 405.2
Section 405.2 covers the current ADA Standards for slope requirements on ramps.
-
Turning Space: ADA Standard Section 809.2.2
All rooms served by an accessible route shall provide a turning space complying with 304....