It should be noted that although side access to the wheelchair space is allowed, companion seating in compliance with Section 11B-802.3 must also be provided adjacent to each wheelchair...
Search Results "Latch Side Clearance"
-
11B-802.1.2 Width
-
1009.5.2 Transfer Space
by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall be centered along a 24 inch (610 mm) minimum side...
-
Are the elements of path of travel and accessible routes substantively the same (such as slope, vertical clearance, width of path of travel, etc.)?
RESPONSE: The terms ACCESSIBLE ROUTE and PATH OF TRAVEL are distinct but related. Accessible route is a fundamental term used to describe, “A continuous unobstructed path connecting...
-
Ground-Level Accessible Routes
The 80-inch clearance applies only to the 60-inch accessible route, and is not required for the entire play area. ...
-
11B-805.4.3 Turning space
A minimum of a 36-inch wide access shall be provided to and along each side of the bed, exam table, procedure table, gurney, lounge chair and/or equipment/apparatus. ...
- Inclusion Solutions Offset Door Hinge
- Smith Carrel Hi-Lo Study Carrel - "The Original"
-
11B-1008.4.2 Clear floor or ground space
These dimensions apply to either forward or side reaches. The reach ranges are appropriate for use with those play components that children seated in wheelchairs may access and reach....
-
11B-1008.4.2 Clear floor or ground space
These dimensions apply to either forward or side reaches. The reach ranges are appropriate for use with those play components that children seated in wheelchairs may access and reach....
-
11B-403.5.1 Clear width
The clear width for aisles shall be 36 inches (914 mm) minimum if serving elements on only one side, and 44 inches (1118 mm) minimum if serving elements on both sides....
-
11B-403.5.1 Clear width
The clear width for aisles shall be 36 inches (914 mm) minimum if serving elements on only one side, and 44 inches (1118 mm) minimum if serving elements on both sides....
-
Clear Floor or Ground Space: ADA Standard Section 1008.4.2
These dimensions apply to either forward or side reaches. The reach ranges are appropriate for use with those play components that children seated in wheelchairs may access and reach....
-
Height: ADA Standard Section 505.4
Section 505.4 covers the current ADA Standards for the height of the top of the gripping surface of handrails.
-
11B-505.4 Height
Sufficient vertical clearance between upper and lower handrails, 9 inches (230 mm) minimum, should be provided to help prevent entrapment. ◼...
-
11B-505.4 Height
Sufficient vertical clearance between upper and lower handrails, 9 inches (230 mm) minimum, should be provided to help prevent entrapment. ◼...
-
406.2.2 Clear height
While the minimum height is required to be 7'-0" by this section, greater vertical clearance is required at van-accessible parking spaces, standard accessible parking spaces, the vehicular...
-
Paperwork Reduction Act
This rule does not contain any paperwork or recordkeeping requirements and does not require clearance under the PRA....
-
R406 Reach Ranges (Section-by-Section Analysis)
R406 Reach Ranges (Section-by-Section Analysis) Forward and side reach ranges must be between 380 millimeters (1.25 feet) and 1220 millimeters (4 feet) above the finish surface....
-
11B-502.6.4.1
The centerline of the International Symbol of Accessibility shall be a maximum of 6 inches (152 mm) from the centerline of the parking space, its sides parallel to the length of the parking...
-
11B-502.6.4.1
The centerline of the International Symbol of Accessibility shall be a maximum of 6 inches (152 mm) from the centerline of the parking space, its sides parallel to the length of the parking...
-
Flush Controls on Toilets
Flush controls shall be located on the open side of the water closet. . 1991 ADA Standards Water Closet Flush Controls shall be mounted on the wide side of toilet areas no more than...
-
Fire Rings, Grills, Fireplaces, and Wood Stoves
In many cases, a 48-inch (1,220-millimeter) -wide ring of clear space must be provided all around (figure 85), because all sides are usable....
-
11B-805.6 Hand washing fixtures, lavatories and sinks
Knee clearance requirement - All accessibility requirements of Section 11B-606 apply to lavatories, sinks and handwashing fixtures required to be accessible....
-
11B-805.6 Hand washing fixtures, lavatories and sinks
Knee clearance requirement - All accessibility requirements of Section 11B-606 apply to lavatories, sinks and handwashing fixtures required to be accessible....