In row seating, two wheelchair spaces shall be permitted to be located side-by-side. [2010 ADAS] Advisory 221.2.3.1 Horizontal Dispersion. ...
Search Results "Latch Side Clearance"
-
11B-221.2.3.1 Horizontal dispersion
-
11B-221.2.3.1 Horizontal dispersion
In row seating, two wheelchair spaces shall be permitted to be located side-by-side. [2010 ADAS] Advisory 221.2.3.1 Horizontal Dispersion. ...
-
11B-221.2.3.1 Horizontal dispersion
In row seating, two wheelchair spaces shall be permitted to be located side-by-side. Advisory 11B-221.2.3.1 Horizontal dispersion....
-
UDI
The starting clearance for each trial was the minimum clearance of the Canadian CSA B651-95 Standard....
-
Station Names: ADA Standard Section 810.6.3
Signs shall be clearly visible and within the sight lines of standing and sitting passengers from within the vehicle on both sides when not obstructed by another vehicle....
-
11B-605.4 Flush controls
Urinals provided in urinal compartments and with hand operated flush controls shall have the controls located on the open side of the urinal....
-
11B-605.4 Flush controls
Urinals provided in urinal compartments and with hand operated flush controls shall have the controls located on the open side of the urinal....
-
Water Closet Centerline and Seat Height
Water closets are to be located so that the centerline is 16 to 18 inches from the side wall compartment partition (604.2)....
-
608.5.3 Alternate Roll-In Type Shower Compartments
Where a seat is provided, the controls, faucets, and shower spray unit shall be located on the side wall adjacent to the seat 27 inches (685 mm) maximum from the side wall behind the seat...
-
604.5.2 Rear Wall
The rear wall grab bar shall be 36 inches (915 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on...
-
Width of Spaces [1012.2]
RVs equipped with a lift need an additional 8 feet of space on the passenger’s side to deploy the lift and to allow people using mobility devices to maneuver onto and off of the lift....
-
608.5.3 Alternate Roll-In Type Shower Compartments
Where a seat is provided, the controls, faucets, and shower spray unit shall be located on the side wall adjacent to the seat 27 inches (685 mm) maximum from the side wall behind the seat...
-
1012.2 Recreational Vehicles
Recreational vehicles equipped with a lift need an additional 8 feet of space on the passenger’s side to deploy the lift and for individuals who use wheeled mobility devices to maneuver...
-
604.5.2 Rear Wall
The rear wall grab bar shall be 36 inches (915 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on...
-
180 Turns Around Obstructions
Additional clearance is required at 180 degree turns around an element that is less than 48” wide....
- Allegion Falcon SC80 Series Surface Mounted Door Control
- Allegion Falcon SC70 Series Surface Mounted Door Control
- Allegion Von Duprin 55 Series Cross Bar Exit Devices
-
211 and 602 Drinking Fountains
1991 Standards require wall and post-mounted cantilevered drinking fountains mounted at a height for wheelchair users to provide clear floor space for a forward approach with knee and toe clearance...
-
7(2)(b)(iv)
(iv) Toilets are located within bathrooms in a manner that permit a grab bar to be installed on one side of the fixture....
-
5.3.4 Grab Bars
In such cases, the riser shall have vertical or nearly vertical sides and a flat area on each side of the seat that is about 3 inches (75 millimeters) wide....
-
Scoping [4.1.3(20)]
Specifications in 4.34.2 and 4.34.3 were modified in June 1993 to allow either a forward or side approach and to provide further guidance on side reach heights....