While the minimum height is required to be 7'-0" by this section, greater vertical clearance is required at van-accessible parking spaces, standard accessible parking spaces, the vehicular...
Search Results "Latch Side Clearance"
-
406.2.2 Clear height
-
306.3.1 General
Space under an element between 9 inches (230 mm) and 27 inches (685 mm) above the finish floor or ground shall be considered knee clearance and shall comply with 306.3....
-
305.7.1 Forward Approach
Figure 305.7.1 Maneuvering Clearance in an Alcove, Forward Approach...
-
305.7.2 Parallel Approach
Figure 305.7.2 Maneuvering Clearance in an Alcove, Parallel Approach...
-
2. Question: What is the minimum width needed for a level boarding railroad passenger station platform to meet the accessibility requirements of the Americans with Disabilities Act (ADA)?
For a conventional level boarding side passenger platform with a railing or a wall on the platform side opposite the track, the minimum platform width should be the sum of the maximum dimensions...
-
Fixed Seating and Tables
At least 27 inches of knee clearance must be provided between the floor and the underside of the table....
-
M305.3 Standing Supports (Section-by-Section Analysis)
in the MDE NPRM preamble on whether the cross section dimensions for gripping surfaces should be applied to standing supports and whether standing supports can provide a 1½ inch minimum clearance...
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
604.2 Location
The water closet shall be positioned with a wall or partition to the rear and to one side....
-
11B-805.6 Hand washing fixtures, lavatories and sinks
Knee clearance requirement - All accessibility requirements of Section 11B-606 apply to lavatories, sinks and handwashing fixtures required to be accessible. ...
-
Clear Floor and Turning Space Inside Examination Rooms
The exam table must have sufficient clear floor space next to it so that an individual using a wheelchair can approach the side of the table for transfer onto it....
-
Grab bar protocol
When transferring to a lower height, with the front grab bar available, and without side guard, 51% (59/115), CI[42%,60%] used the front bar, and 20% (23/111), CI[12%,25%] could transfer...
- Allegion Falcon SC80 Series Surface Mounted Door Control
- Allegion Falcon SC70 Series Surface Mounted Door Control
- Allegion Von Duprin 55 Series Cross Bar Exit Devices
-
8.2 READING AND STUDY AREAS
Clearances between fixed accessible tables and study carrels shall comply with 4.3....
-
11B-221.2.3.1 Horizontal dispersion
In row seating, two wheelchair spaces shall be permitted to be located side-by-side. [2010 ADAS] Advisory 221.2.3.1 Horizontal Dispersion. ...
-
11B-221.2.3.1 Horizontal dispersion
In row seating, two wheelchair spaces shall be permitted to be located side-by-side. [2010 ADAS] Advisory 221.2.3.1 Horizontal Dispersion. ...
-
11B-221.2.3.1 Horizontal dispersion
In row seating, two wheelchair spaces shall be permitted to be located side-by-side. Advisory 11B-221.2.3.1 Horizontal dispersion....
-
3.3.16 Door Use
The difference in rating was therefore more likely to have been influenced by the latch side clearance than door size, especially on the pull side....
- Hill-Rom Golvo® 8000 / 8008 Patient Lift
-
Water Closet Centerline and Seat Height
Water closets are to be located so that the centerline is 16 to 18 inches from the side wall compartment partition (604.2)....
-
608.5.3 Alternate Roll-In Type Shower Compartments
Where a seat is provided, the controls, faucets, and shower spray unit shall be located on the side wall adjacent to the seat 27 inches (685 mm) maximum from the side wall behind the seat...
-
Width of Spaces [1012.2]
RVs equipped with a lift need an additional 8 feet of space on the passenger’s side to deploy the lift and to allow people using mobility devices to maneuver onto and off of the lift....