(1) Handrails shall be continuous along both sides of stairs. The inside handrail on switchback or dogleg stairs shall always be continuous (see Fig. 19(a) and (b))....
Search Results "Hinge Side Clearance"
Commonly Searched Documents
-
4.9.4(1)
-
Handrails [4.9.4]
Continuous handrails are required along both sides of stairs. A center rail is not specified for wide stairways by ADAAG but may be required by local building or life safety codes....
-
§ 38.23(c)(4) Ramp barriers
Each side of the ramp shall have barriers at least 2 inches high to prevent mobility aid wheels from slipping off....
-
GUARD [DSA-AC, HCD 1, HCD 2 & HCD 1-AC] OR GUARDRAIL
A building component or a system of building components located at or near the open sides of elevated walking surfaces that minimizes the possibility of a fall from the walking surface to...
-
Standing Supports (M304.3 and M305.3)
M304.3 would require standing supports to be provided on each side of the standing surface on diagnostic equipment used by patients in a standing position....
-
603 Toilet and Bathing Rooms
Doors are not permitted to swing into clear floor space or clearance required for any fixture except under certain conditions (603.2.3)....
-
4.31.2 CLEAR FLOOR OR GROUND SPACE
Figure 44 Mounting Heights and Clearances for Telephones...
-
1133B.2.3.2
greater than 10 and it is determined that compliance with Section 1133B.2.3 would create an unreasonable hardship, a projection of 5/8 inch (16 mm) maximum will be permitted for the latch side...
-
4.3.3 Clear Floor Area
The clear floor area width also informs the minimum clearance width for successful passage through corridors, doorways and ramps....
- Bobrick TrimLineSeries Countertop Mounted Paper Towel Dispenser B-526
- American Standard AquaWash Telescoping Bidet Seat 5900A.05G
-
M303.3.3.4 Edge Protection
Ramps with drop offs ½ inch (13 mm) or greater shall provide edge protection 2 inches (50 mm) high minimum on each side with a drop off....
-
R304.5.1 Width
The clear width of curb ramp runs (excluding any flared sides), blended transitions, and turning spaces shall be 1.2 m (4.0 ft) minimum....
-
407.8.1 Vertical Reference Plane
Operable parts shall be positioned for a side reach or a forward reach determined with respect to a vertical reference plane....
-
5c.
Are the highest floor control buttons in the elevator cab mounted no more than 54 inches above the floor for a side reach or 48 inches for forward reach? Yes _____ No _____...
-
407.12.1 Vertical Reference Plane
Operable parts shall be positioned for a side reach or a forward reach determined with respect to a vertical reference plane....
-
4.30.6 MOUNTING LOCATION AND HEIGHT
Interior signage shall be located alongside the door on the latch side and shall be mounted at a height of between 54 in and 66 in (1370 mm and 1675 mm) above the finished floor....
-
4.34.5.2(1)
The water closet may be located with the clear area at either the right or left side of the toilet....
- AJW Architectural Products U685 Series Dual Toilet Tissue Dispenser & Sanitary Napkin Disposal - Partition Mounted
-
Common Problems with Signs
Problems with Signs Ø Some signs – such as permanent room signs – are required to have Braille, high contrast, and raised lettering and must be located on the wall to the latch side...
-
Motorized Kick Scooters
Because the user does not normally need to push, these scooters often have a platform wide enough for two adult feet side by side....
-
11B-608.3.2 Standard roll-in type shower compartments
Grab bars shall be provided on the back wall and the side wall opposite the seat. Grab bars shall not be provided above the seat....
- Eliason Corporation RMR-1500 Traffic Door (Chase Doors - Durulite Retailer Door)
-
409.4.6.2 Location
Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall. Figure 409.4.6.2 Location of Private Residence Elevator Control Panel...