In a two story town hall built in 1968 that doesn’t have an elevator, staff on the second floor could meet with citizens on the first floor if meeting space is comparable to that on the...
Search Results "Elevator Landing"
Commonly Searched Documents
-
Do all state and local buildings need to be accessible (comply with the ADA Standards for Accessible Design?)
-
1007.7.2 Outdoor facilities
Every required exterior area of assisted rescue shall have direct access to an interior exit stairway, exterior stairway, or elevator serving as an accessible means of egress component....
-
§ 35.151(c)(1)
commence after July 26, 1992, but prior to September 15, 2010, then new construction and alterations subject to this section must comply with either UFAS or the 1991 Standards except that the elevator...
-
206.3 Location--Modification to 206.3 of Appendix B to 36 CFR Part 1191
Elements such as ramps, elevators, or other circulation devices, fare vending or other ticketing areas, and fare collection areas shall be placed to minimize the distance which wheelchair...
-
Over-the-Road Bus
The ADA definition focuses on a bus with an elevated passenger deck over a baggage compartment (i.e., a "Greyhound-type'' bus)....
- Community Resources for Independent Living - Hayward, Fremont, Livermore, Anaheim, CA
-
II-5.1000 General
The courthouse has no elevator or other means of access to the second floor....
-
§35.151 New Construction and Alterations
Because permitting the elevator exemption would clearly result in application of a lesser standard than that applied under section 504, paragraph (c) states that the elevator exemption does...
-
§35.151 New construction and alterations. (Section-by-Section Analysis)
Because permitting the elevator exemption would clearly result in application of a lesser standard than that applied under section 504, paragraph (c) states that the elevator exemption does...
- AquaTrek2 ADA Step System
-
11B-407.4.9 Emergency communication
Emergency two-way communication systems between the elevator and a point outside the hoistway shall comply with ASME A17.1. [2010 ADAS] 407.4.9 Emergency Communication. ...
-
409.1 General
Private residence elevators that are provided within a residential dwelling unit required to provide mobility features complying with 809.2 shall comply with 409 and with ASME A17.1 (incorporated...
-
703.3.2 Position
EXCEPTION: Braille provided on elevator car controls shall be separated 3/16 inch (4.8 mm) minimum and shall be located either directly below or adjacent to the corresponding raised characters...
-
703.3.2 Position
EXCEPTION: Braille provided on elevator car controls shall be separated 3/16 inch (4.8 mm) minimum and shall be located either directly below or adjacent to the corresponding raised characters...
-
Egress [4.1.3(9), 4.3.10]
In multi-story buildings where stories are located above or below the level of exit discharge, evacuation elevators can be used as part of an accessible means of egress....
-
11B-703.5.6 Height from finish floor or ground
Visual characters indicating elevator car controls shall not be required to comply with Section 11B-703.5.6. 2....
-
11B-407.4.9 Emergency communication
Emergency two-way communication systems between the elevator and a point outside the hoistway shall comply with ASME A17.1. [2010 ADAS] 407.4.9 Emergency Communication....
-
11B-407.4.9 Emergency communication
Emergency two-way communication systems between the elevator and a point outside the hoistway shall comply with ASME A17.1. [2010 ADA Standards] 407.4.9 Emergency Communication....
-
11B-703.3.2 Position
Exception: Braille provided on elevator car controls shall be separated 3/16 inch (4.8 mm) minimum and shall be located directly below the corresponding raised characters or symbols....
-
206.2.8 Employee Work Areas
Large pieces of equipment, such as electric turbines or water pumping apparatus, may have stairs and elevated walkways used for overseeing or monitoring purposes which are physically part...
-
206.2.7 Press Boxes
For example, if a university has a soccer stadium with three press boxes elevated 12 feet (3660 mm) or more above grade and each press box is 150 square feet (14 m2), then the aggregate...
-
206.2.8 Employee Work Areas
Large pieces of equipment, such as electric turbines or water pumping apparatus, may have stairs and elevated walkways used for overseeing or monitoring purposes which are physically part...
-
Standards Applicable Under Section 504 as of March 15, 2012
Between 1/26/92 and 9/14/10 UFAS or 1991 Standards without the elevator exception....
-
11B-703.3.2 Position
Exception: Braille provided on elevator car controls shall be separated 3/16 inch (4.8 mm) minimum and shall be located directly below the corresponding raised characters or symbols....