Buttons with floor designations shall be provided with visible indicators to show that a call has been registered....
Search Results "Centered Clear Floor Space"
-
11B-407.4.7.1.4 Visible indicators
-
11B-703.5.9 Line spacing
11B-703.5.9 Line spacing. Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height....
-
4.10.12(3)
All floor buttons shall be no higher than 48 in (1220 mm), unless there is a substantial increase in cost, in which case the maximum mounting height may be increased to 54 in (1370 mm),...
-
203.9 Employee Work Areas
Spaces and elements within employee work areas shall only be required to comply with 206.2.8, 207.1, and 215.3 and shall be designed and constructed so that individuals with disabilities...
-
4.34.5.4(1) Floor space
(1) Floor space. Clear floor space at bathtubs shall be as shown in Fig. 33....
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
11B-604.8.1.1.2 Maneuvering space with side-opening door....
-
407.4.7.1.4 Visible Indicators
Buttons with floor designations shall be provided with visible indicators to show that a call has been registered....
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep maneuvering space...
-
11B-221.2 Wheelchair spaces
Wheelchair spaces complying with Section 11B-221.2 shall be provided in assembly areas with fixed seating. Advisory 11B-221.2 Wheelchair spaces....
-
11B-703.5.9 Line spacing
Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height. [S.H. ...
-
11B-221.2.3.1 Horizontal dispersion
Wheelchair spaces shall be dispersed horizontally....
-
11B-221.2.3.1 Horizontal dispersion
Wheelchair spaces shall be dispersed horizontally....
-
11B-809.7.1 Width
The clear width for the accessible route shall be 36 inches (914 mm) minimum. Exception: The clear width shall be permitted to be reduced to 32 inches (813 mm) minimum at doors....
-
T502.4 Doorways with Steps on Over-the-Road Buses
On over-the-road buses, doorways with steps shall provide an opening with a clear width of 30 inches (760 mm) minimum. Exceptions: 1....
-
14. In § 38.93(d)(3)
§ 38.93 [Amended] 14. In § 38.93(d)(3), remove the period at the end of the paragraph and add the following words: “,ensuring compliance with section 37.42, where applicable.” in...
-
4.3.6 Surface Textures
The surface of an accessible route shall comply with 4.5.
-
4.3.6 SURFACE TEXTURES
The surface of an accessible route shall comply with 4.5.
-
§ 38.93(d) Coordination with boarding platform
(d) Coordination with boarding platform—
-
503.4 Floor and Ground Surfaces
503.4 Floor and Ground Surfaces. Vehicle pull-up spaces and access aisles serving them shall comply with 302....
-
Horizontal Dispersion: ADA Standard Section 221.2.3.1
Section 221.2.3.1 covers scoping requirements in the current ADA Standards for horizontal Dispersion in assembly areas.
-
11B-405.2 Slope
EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes steeper than 1:12 complying with Table 405.2 where such slopes are necessary due to space...
-
11B-405.2 Slope
EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes steeper than 1:12 complying with Table 405.2 where such slopes are necessary due to space...
-
M303.2 Wheelchair Spaces
Wheelchair spaces complying with M303.2 shall be provided at diagnostic equipment....