Areas of refuge located within a stairway enclosure. 2....
Search Results "Wet Location"
-
1003.2.13.5.2 Separation
-
§ 38.125(a)(1) General
., lift, ramp or bridge plate) complying with either paragraph (b) or (c) of this section and sufficient clearances to permit a wheelchair or other mobility aid user to reach a seating location...
-
11B-1009.2.3 Clear deck space
The space shall be 36 inches (914 mm) wide minimum and shall extend forward 48 inches (1219 mm) minimum from a line located 12 inches (305 mm) behind the rear edge of the seat....
-
11B-1009.2.3 Clear deck space
The space shall be 36 inches (914 mm) wide minimum and shall extend forward 48 inches (1219 mm) minimum from a line located 12 inches (305 mm) behind the rear edge of the seat....
-
11B-220.1.2 Two automatic teller machines or fare machines
Where two automatic teller machines or fare machines are provided at a location, one shall comply with Sections 11B-707.2 through 11B-707.8 and one shall comply with Sections 11B-309 _|Operable...
-
4.7.1 General
In alterations, where a condition for exception in section 1.1 prohibits full compliance with a specific requirement for clear floor or ground space surface, slope, size, or location, the...
-
§27.71(i)(1)
1) Airport operators must enable or ensure high-contrast captioning at all times on all televisions and other audio-visual displays that are capable of displaying captions and that are located...
-
4.1.7(3)(e)
(e) Displays and written information, documents, etc., should be located where they can be seen by a seated person....
-
III-5.4300 Transportation terminals
all passenger services in a two-story facility - including boarding, debarking, loading and unloading, baggage claim, dining facilities, and other common areas open to the public - are located...
-
Visual Characters
Visual characters are required to be located at least 40 inches high (703.5.6)....
-
Are there any situations in which an animal would not be permitted to accompany its user on the flight?
FAA or applicable foreign government safety regulations, must remain unobstructed (e.g., an aisle, access to an emergency exit) AND the passenger and animal cannot be moved to another location...
-
Temporary Solutions for Election Day
Suggestion: When people who are blind or who have low vision use a cane to detect hazards, objects located at 27 inches or lower are detectable....
-
11B-213.3.4 Lavatories
Where lavatories are provided, at least ten percent but no fewer than one shall comply with Section 11B-606 and shall not be located in a toilet compartment. ...
-
R309.2.2 Narrow Sidewalks
When an access aisle is not provided, the parking spaces shall be located at the end of the block face. Advisory R309.2.2 Narrow Sidewalks....
-
1007.6.2 Separation
Exceptions: Areas of refuge located within a stairway enclosure....
-
1007.6.3 Two-way communication
Location of the central control point shall be approved by the fire department. The two-way communication system shall include both audible and visible signals....
-
216.9.2 Directional Signs
Directional signs indicating the location of the nearest public TTY shall be provided at all banks of public pay telephones not containing a public TTY....
-
Dispersion
Where only portions of a floor are accessible, such as wheelchair seating in assembly areas, be sure to locate wheelchair accessible units in proximity to, and on an accessible route from...
-
9. Sidewalks of Other Governmental Agencies
Within two years, the City will identify the locations of the Pedestrian Facilities that the City believes are immediately adjacent to such governmental facilities....
-
4.34.6.6* RANGES AND COOKTOPS
The location of controls for ranges and cook-tops shall not require reaching across burners....
-
10.3.1(15)
Clocks shall be placed in uniform locations throughout the facility and system to the maximum extent practicable....
-
Mirror Height
The ANSI A117.1‒2003 standard contains a new requirement that specifies a height of 35 inches maximum for accessible mirrors not located above a lavatory or counter top....
-
11B-802.1.3 Depth
A single wheelchair location space with side entry must functionally be usable as if it were within an alcove, requiring the user to maneuver back and forth to get into position, and thus...
-
1009.9 Signage
Additionally, visual characters, raised character and braille signage complying with Chapter 11A, Section 1143A and Chapter 11B, Sections 11B-703.1, 11B-703.2, 11B-703.3 and 11B-703.5 shall be located...