Alterations. (Section-by-Section Analysis)
-
11B-407.2.1.5 Signals
Existing elevators shall not be required to comply with 407.2.1.5....
-
11B-407.2.1.2 Size and shape
[2010 ADAS] EXCEPTION: Existing elevator call buttons shall not be required to comply with 407.2.1.2....
-
§ 37.135(c)(1)
ETA Editor's Note The above referenced section 37.138 does not currently exist, according to ecfr.gov....
-
11B-407.4.6.1 Location
In existing elevators, car control buttons with floor designations shall be permitted to be located 54 inches (1372 mm) maximum above the finish floor where a parallel approach is provided...
-
907.5.2.3.3 Group R-2
interconnection of the building fire alarm system with the unit smoke alarms, replacement of audible appliances with combination audible/visible appliances, or future extension of the existing...
-
11B-407.2.1.2 Size and shape
[2010 ADA Standards] EXCEPTION: Existing elevator call buttons shall not be required to comply with 407.2.1.2....
-
11B-407.2.1.5 Signals
Existing elevators shall not be required to comply with 407.2.1.5....
-
407.2.2.2 Visible Signals
Existing elevators shall not be required to comply with 407.2.2.2....
-
407.4.6.1 Location
In existing elevators, car control buttons with floor designations shall be permitted to be located 54 inches (1370 mm) maximum above the finish floor where a parallel approach is provided...
-
608.7 Thresholds
EXCEPTION: A threshold 2 inches (51 mm) high maximum shall be permitted in transfer type shower compartments in existing facilities where provision of a 1/2 inch (13 mm) high threshold would...
-
407.2.2.1 Visible and Audible Signals
In existing elevators, a signal indicating the direction of car travel shall not be required....
-
11B-604.4 Seats
A 3-inch (76 mm) high seat shall be permitted only in alterations where the existing fixture is less than 15 inches (381 mm) high....
-
11B-604.4 Seats
A 3-inch (76 mm) high seat shall be permitted only in alterations where the existing fixture is less than 15 inches (381 mm) high....
-
A11yNYC - Accessibility New York City
Our group exists to advance digital accessibility and inclusive design. Our goal is to bring together NYC's accessibility community to share ideas, best practices, and our experiences....
- Federal Elevator Carelift Wheelchair Lift
- SafetyStepTD Ramp-Up Detectable Warning System
- SafePath BigHorn™ Ramps
- SafePath VulcanLanding™ Rubber Transition Ramp
- AssistiveWare News-2-You
-
5. Compare Surface Options
The planning team should embark on a purposeful mission to determine the playground surface system most appropriate for their site and operational resources....
-
Purpose and Legal Authority
(including buses, vans, and fixed guideway systems), and amended these guidelines in 1998 to include accessibility requirements for OTRBs.1 Given the passage of nearly two decades, the existing...
-
FAQ: What is "Corada WorkSpace?"
Loading this data into Corada allows it to be integrated with Corada’s existing database of other accessibility-related material, so users’ content will be in context with applicable federal...
-
DOT Response to Comments
This existing requirement applies to nearly all public transportation entities....