An expansion, extension, or increase in the gross floor area or height of a building or facility....
Search Results "Floor Identification"
Commonly Searched Documents
-
Addition
-
5.3.2.2 Surface
The surface of the turning space and clear floor or ground space shall be firm and stable....
-
6b.
Is the change in level from the floor to the lift surface ramped or beveled? Yes _____ No _____...
-
307.4 Vertical Clearance
The leading edge of such guardrail or barrier shall be located 27 inches (685 mm) maximum above the finish floor or ground....
-
407.2.1.4 Location
A destination-oriented elevator system provides lobby controls enabling passengers to select floor stops, lobby indicators designating which elevator to use, and a car indicator designating...
-
407.2.1.4 Location
A destination-oriented elevator system provides lobby controls enabling passengers to select floor stops, lobby indicators designating which elevator to use, and a car indicator designating...
-
407.2.1.4 Location
A destination-oriented elevator system provides lobby controls enabling passengers to select floor stops, lobby indicators designating which elevator to use, and a car indicator designating...
-
9.5.1 New Construction
EXCEPTION: Where elevators are not provided as allowed in 4.1.3(5), accessible amenities are not required on inaccessible floors as long as one of each type is provided in common areas on...
-
9.4 POST OFFICE BOXES
Accessible post office boxes shall be located in the second or third set of modules from the floor, approximately 12 in to 36 in (305 mm to 915 mm) above the finished floor....
-
Sec.36.403(c)(1)(ii)
(ii) Replacing an inaccessible floor surface in the customer service or employee work areas of a bank;...
-
Coin Slot Height
Is it mounted with the coin slot no higher than 54" above the floor? Yes __ No __ N/A __ Comments: ___________________________________________...
-
Handset Reach Range
Is it mounted with the handset cradle no higher than 54" above the floor? Yes __ No __ N/A __ Comments: ___________________________________________...
-
§ 36.403(c)(1)(ii)
(ii) Replacing an inaccessible floor surface in the customer service or employee work areas of a bank;...
-
4.9.4(6)
(6) Ends of handrails shall be either rounded or returned smoothly to floor, wall or post....
-
4.8.5(6)
(6) Ends of handrails shall be either rounded or returned smoothly to floor, wall, or post....
-
4.7.9.4 Depth
The bottom of the bowl shall be at least 15 inches (380 mm) above the floor or ground....
-
[A] ADDITION
[DSA-AC] An expansion, extension, or increase in the gross floor area or height of a building or facility....
-
ADDITION
[DSA-AC] An expansion, extension or increase in the gross floor area or height of a building or facility....
-
604.8.1.4 Toe Clearance
The front partition and at least one side partition shall provide a toe clearance of 9 inches (230 mm) minimum above the finish floor and 6 inches (150 mm) deep minimum beyond the compartment-side...
-
604.7 Dispensers
The outlet of the dispenser shall be 15 inches (380 mm) minimum and 48 inches (1220 mm) maximum above the finish floor and shall not be located behind grab bars....
-
404.2.3 Clear Width
There shall be no projections into the required clear opening width lower than 34 inches (865 mm) above the finish floor or ground....
-
Technical Memorandum TM 2012-04 Multi-Story Buildings and Facilities
The term “story” is defined in 106.5.64 as that portion of a building or facility designed for human occupancy included between the upper surface of a floor or the upper surface of the floor...
-
604.8.1.4 Toe Clearance
The front partition and at least one side partition shall provide a toe clearance of 9 inches (230 mm) minimum above the finish floor and 6 inches (150 mm) deep minimum beyond the compartment-side...
-
404.2.3 Doorways - Clear Width
There shall be no projections into the required clear opening width lower than 34 inches (865 mm) above the finish floor or ground....