Located within the area of the theater in which the vertical viewing angles (as measured to the top of the screen) are from the 40th to the 100th percentile of vertical viewing angles for...
Search Results "Curb Ramp Top Landing"
Commonly Searched Documents
-
11B-221.2.1.5 Stadium-style movie theaters
- ASTM International
-
36 CFR Part 1191 ABA Accessibility Guidelines, Outdoor Developed Areas
outdoor areas developed for recreational purposes: Department of Agriculture (Forest Service); Department of Defense (Army Corps of Engineers); and Department of the Interior (Bureau of Land...
-
C1-f
If the slope of part of the accessible route is more than 1:20, does it meet the following requirements for an accessible ramp? Yes No...
-
4.1.3(4)
(4) Interior and exterior stairs connecting levels that are not connected by an elevator, ramp, or other accessible means of vertical access shall comply with 4.9....
-
A4.9.1 Minimum Number
Only interior and exterior stairs connecting levels that are not connected by an elevator, ramp, or other accessible means of vertical access have to comply with 4.9....
-
1009.3.3 Handrails
Handrail extensions specified by 505.10.1 shall not be required at the bottom landing serving a sloped entry. 2....
-
Power-Operated Doors or Gates
In addition, the Board has added clarification, consistent with the ANSI standard, that the exception in section 410.5 does not apply to platform lifts serving more than two landings....
-
1009.3.3 Handrails
Handrail extensions specified by 505.10.1 shall not be required at the bottom landing serving a sloped entry. 2....
-
1009.3.3 Handrails
Handrail extensions specified by 505.10.1 shall not be required at the bottom landing serving a sloped entry. 2....
-
11B-1009.3.3 Handrails
Exceptions: Handrail extensions specified by Section 11B-505.10.1 shall not be required at the bottom landing serving a sloped entry....
-
E1-d
Where the slope of the accessible route is greater than 1:20, does this area meet the following requirements for an accessible ramp? Yes No...
-
III-7.5110 Stairs
Interior and exterior stairs must comply if they go between levels not connected by an elevator, ramp, or lift....
-
A MINIMUM HIGHEST POINT STANDARD OF 19 INCHES IS CONSISTENT WITH EXISTING ACCESSIBILITY STANDARDS
The height of water closet seats shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the floor, measured to the top of the seat....
- Cole & Associates, Inc.
-
Stabila slope meter is easy to read
I like this slope meter because of the readings provided on the top and the side of the slope meter. Makes documentation with photos very easy in the field....
-
9. Platform lift
Platform lift 4.11 May be used in lieu of an elevator or ramp under certain conditions....
-
10.2.2(1)
(1) Bus stop sites shall be chosen such that, to the maximum extent practicable, the areas where lifts or ramps are to be deployed comply with section 10.2.1(1) and (2)....
-
§ 38.29(a)
(a) Interior handrails and stanchions shall permit sufficient turning and maneuvering space for wheelchairs and other mobility aids to reach a securement location from the lift or ramp....
-
1.9.1.1.5
1.9.1.1.5 With respect to buildings, structures, sidewalks, curbs and related facilities not requiring a building permit, building standards published in the California Building Standards...
-
Course Barriers
Course Barriers Curbing or other man-made barriers often line golf car paths to restrict golf cars from entering certain portions of the course or to reduce erosion....
-
603.3 Mirrors
In order for mirrors to be usable by people who are ambulatory and people who use wheelchairs, the top edge of mirrors should be 74 inches (1880 mm) minimum from the floor or ground....
-
603.3 Mirrors
In order for mirrors to be usable by people who are ambulatory and people who use wheelchairs, the top edge of mirrors should be 74 inches (1880 mm) minimum from the floor or ground....
-
Grab Bars
The top of the gripping surface must be 4 to 6 inches above the wall to provide leverage to the person using the bars....