around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear floor space...
Search Results "Wheelchair Space"
Commonly Searched Documents
-
604.3.2 Overlap
-
604.3.2 Overlap
around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear floor space...
-
1012.3 Other Vehicles
This section requires parking spaces for vehicles, other than recreational vehicles, to be 16 feet wide minimum to accommodate vans equipped with a lift or ramp....
-
Work Areas [4.1.1(3)]
Work areas must be accessible for "approach, entry, and exit," which means location on an accessible route so that people using wheelchairs can enter and back out of the space....
-
222 and 803 Dressing, Fitting, and Locker Rooms
Commenters explained that meeting the new requirement would result in a loss of sales and inventory space....
-
11B-703.3.2 Position
Editor's Note 2013 CBC Figure 11B-703.3.2 is not intended to suggest that Braille must be multi-lined when the related text is multi-lined, only to illustrate the required position and spacing...
-
11B-703.3.2 Position
ETA Editor's Note CBC Figure 11B-703.3.2 is not intended to suggest that Braille must be multi-lined when the related text is multi-lined, only to illustrate the required position and spacing...
-
11B-703.3.2 Position
Editor's Note CBC Figure 11B-703.3.2 is not intended to suggest that braille must be multi-lined when the related text is multi-lined, only to illustrate the required position and spacing...
-
11B-904.4.1 Parallel approach
A clear floor or ground space complying with Section 11B-305 shall be positioned for a parallel approach adjacent to the 36 inch (914 mm) minimum length of counter....
-
11B-904.4.1 Parallel approach
A clear floor or ground space complying with Section 11B-305 shall be positioned for a parallel approach adjacent to the 36 inch (914 mm) minimum length of counter....
-
11B-503.5 Vertical clearance
Vehicle pull-up spaces, access aisles serving them, and a vehicular route from an entrance to the passenger loading zone and from the passenger loading zone to a vehicular exit shall provide...
-
11B-902.4.1 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for forward approach shall be provided....
-
11B-902.4.1 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for forward approach shall be provided....
-
11B-904.4.1 Parallel approach
A clear floor or ground space complying with Section 11B-305 shall be positioned for a parallel approach adjacent to the 36 inch (914 mm) minimum length of counter....
-
F202.6.2 Accessible Route
Elements and spaces required to be accessible by F202.6 shall be on an accessible route complying with F206....
-
Looking at Cal Green 5.106.5.3, we must provide the conduits and panel capacity for future installation for the required number of spaces (2 in this case). However, it is only when the equipment is to be installed that we need to refer to CBC and CEC. Section 11B-228.3.1 also reiterates this. Therefore, we would show the location of the conduit stub outs adjacent to 2 current parking spaces and would show space on the electric panel for the future equipment – and that is all. At this time, we do not need to show the requirements for EV accessibility when equipment is installed per Chapter 11B. Is my interpretation correct?
RESPONSE: CBC Chapter 11B accessibility provisions for EVCS apply when a project consists of one or more electric vehicle charging spaces served by an electric vehicle charger or other charging...
-
11B-812.7.2 Marking
Access aisles at vehicle spaces shall be marked with a painted borderline around their perimeter....
-
Resting Intervals [1017.8]
A turning space that complies with section 304.3.2 of the ABA Standards must be provided....
-
1012.5 Slope
The slope of the surface of parking spaces and pull-up spaces shall not be steeper than 1:48 in any direction....
-
904.4.1 Parallel Approach
A clear floor or ground space complying with 305 shall be positioned for a parallel approach adjacent to the 36 inch (915 mm) minimum length of counter....
-
2) Where the Standard says "Changes in level are not permitted"
2) Where the Standard says "Changes in level are not permitted", such as 304.2 for turning spaces: Here the standard is followed by an unenforceable advisory that says, "As used in this...
-
T215.1 General
Communication features on non-rail vehicles shall comply with T215.
-
T215 Communication Features
[See subsections ...]