Gates which must be pushed open by wheelchair or mobility aid users shall have a smooth continuous surface extending from 2 inches above the floor to 27 inches above the floor....
Search Results "Ramp Surface"
-
10.4.1(5)
-
M301.2.1 Height
The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured from the floor to the top of the transfer surface....
-
5.3.3.1 Transfer Sides Recommendation for Exam Chairs with Fixed Footrests
The Committee recommends exam chairs with a fixed footrest have a transfer surface minimum of a 17 inch depth and a 21 inch width located on both sides of the chair to allow for a left or...
-
11B-805.7 Built-in cabinets and work surfaces
Built-in cabinets, counters and work surfaces shall be accessible, including: patient wardrobes, nurse’s stations, administrative centers, reception desks, medicine preparation areas, laboratory...
-
1.1.9 Horizontal gaps and vertical alignment
horizontal discontinuities and variations in vertical alignment such as at concrete joints, gaps, grade breaks, and at the interface of concrete with other materials or elements built into the surface...
- SafePath: Sport Floor Reducers for ADA and Disability Access
-
Cross Slope
Cross Slope The cross slopes of gangways, transition plates and floating piers that are part of an accessible route must be designed and constructed not to exceed a maximum of 2...
-
Addendum D: Comparison of demographics and transfer height between Phase 1 and Phase 2 of the study
[See subsections ...]
-
Electronic instruments
Electronic instruments have been developed to measure floor flatness. Originally created to measure the flatness of concrete floors in critical applications such as narrow - aisle...
-
Circular Cross Section and Clearance (§505.5, §505.7)
Circular Cross Section and Clearance
-
11B-805.7 Built-in cabinets and work surfaces
Built-in cabinets, counters and work surfaces shall be accessible, including: patient wardrobes, nurse’s stations, administrative centers, reception desks, medicine preparation areas, laboratory...
- Smith Carrel Hi-Lo Study Carrel - "The Original"
-
5. Edge Protection
The MDE NPRM proposed edge protection on the ramps leading up to the raised platform (proposed M303.3.3.4), but did not require edge protection on the raised platforms themselves....
- EZ Dock EZ Launch® System for Kayaks and Canoes
-
2.1 Parking
Are there usable ramps or curb cuts onto the sidewalks? How far away from the entrance is the accessible parking?...
-
Boarding and Deplaning Assistance Where Level-Entry Boarding is Unavailable
enplanements where level-entry boarding is not available [Secs. 382.40(a) and 382.40a(a)], carriers must provide boarding assistance to passengers with a disability using mechanical lifts, ramps...
-
Wheeled Mobility Anthropometry Project
The data and recommendations from the Wheeled Mobility Anthropometry Project are discussed in connection with the following technical criteria: • Height of transfer surfaces on diagnostic...
-
Ramp
Ramp: A ramped surface was designed to insert between two steps and serve as an integrated sliding board to assist with the transfers by bridging the gap between steps. ...
-
M305.3.2.1 Horizontal Position
The height of the top of the gripping surface on horizontal standing supports shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum above the standing surface....
-
M302.2.5 Unobstructed Transfer
Each transfer side complying with M302.2.4 shall provide unobstructed access to transfer surfaces. EXCEPTIONS: 1....
-
5.4.2.2 Transfer and Positioning Support Length for Imaging Equipment with Transfer Surfaces
5.4.2.2 Transfer and Positioning Support Length for Imaging Equipment with Transfer Surfaces....
- Pilot Rock N-20 Series Charcoal Grill
-
Implication for Standards and Design
The station used in this second phase permitted greater freedom of wheelchair positioning around the transfer surface compared to the first phase station. ...