Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height....
Search Results "Minimum Dimension"
-
703.5.9 Line Spacing
-
1009.2.8 Submerged Depth
The lift shall be designed so that the seat will submerge to a water depth of 18 inches (455 mm) minimum below the stationary water level....
-
703.5.7 Stroke Thickness
Stroke thickness of the uppercase letter "I" shall be 10 percent minimum and 30 percent maximum of the height of the character....
-
407.4.8.2.2 Signal Level
The verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the annunciator....
-
407.4.5 Illumination
The level of illumination at the car controls, platform, car threshold and car landing sill shall be 5 foot candles (54 lux) minimum....
-
1005.3.1 Curb or Barrier
Curbs or barriers shall extend 2 inches (51 mm) minimum above the surface of the fishing pier or platform....
-
706.5 Signal-to-Noise Ratio
The signal-to-noise ratio for internally generated noise in assistive listening systems shall be 18 dB minimum....
-
1009.4.2 Height
The height of the transfer wall shall be 16 inches (405 mm) minimum and 19 inches (485 mm) maximum measured from the deck....
-
1002.4.5 Ride Entry
Openings providing entry to wheelchair spaces on amusement rides shall be 32 inches (815 mm) minimum clear....
-
606.4 Faucets
Hand-operated metering faucets shall remain open for 10 seconds minimum....
-
1134A.5, Item 2
bathtub is installed with surrounding walls, grab bar reinforcement shall be located on each end of the bathtub, 32 inches to 38 inches (813 mm to 965 mm) above the floor, extending a minimum...
-
1134A.5, Item 2
bathtub is installed with surrounding walls, grab bar reinforcement shall be located on each end of the bathtub, 32 inches to 38 inches (813 mm to 965 mm) above the floor, extending a minimum...
-
Height
The Access Board is considering whether 6 inches minimum and 19 inches maximum above the transfer surface would be an appropriate height for transfer supports on diagnostic equipment used...
-
11B-405.5 Clear width
The clear width of a ramp run shall be 48 inches (1219 mm) minimum. Exceptions: 1....
-
11B-405.5 Clear width
The clear width of a ramp run shall be 48 inches (1219 mm) minimum....
-
11B-223.1.1 Alterations
Section 11B-223 shall apply only to the patient bedrooms or resident sleeping rooms being altered or added until the number of patient bedrooms or resident sleeping rooms complies with the minimum...
-
11B-704.3 Volume control telephones
Public telephones required to have volume controls shall be equipped with a receive volume control that provides a gain adjustable up to 20 dB minimum....
-
F219.3 Receivers
Twenty-five percent minimum of receivers provided, but no fewer than two, shall be hearing-aid compatible in accordance with 706.3. [ECTCR UFAS 4.1.2(18)(b)] EXCEPTIONS: 1....
-
1016.4 Passing Spaces
Entities should consider providing either 60 inches minimum clear width on outdoor recreation access routes or passing spaces at shorter intervals where the route is heavily used or adjoins...
-
11B-704.3 Volume control telephones
Public telephones required to have volume controls shall be equipped with a receive volume control that provides a gain adjustable up to 20 dB minimum....
-
219.3 Receivers
Twenty-five percent minimum of receivers provided, but no fewer than two, shall be hearing-aid compatible in accordance with 706.3. EXCEPTIONS: 1....
-
5.4.1.2 Transfer and Positioning Support Location Recommendations for Imaging Equipment with Transfer Surfaces
The Committee used a 24-inch dividing point for table width to accommodate the dimensions for the maximum reach range....
-
General: ADA Standard Section 232.1
Section 232.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for detention facilities and correctional facilities.
- Viking K-1600-EHFA Elevator Phone with Built-in Dialer and Digital Announcer