Access Board's Note to Reader: The Department of Justice’s ADA standards also require the following: Housing at a place of education. ...
Search Results "Proposed Standard"
-
11B-224.7.2 Multi-bedroom housing units with adaptable features
-
Sec.36.304(g)(2)
(2) To the extent that relevant standards for alterations are not provided in subpart D of this part, then the requirements of Sec.36.304 shall not be interpreted to exceed the standards...
-
Can lifts be attendant-operated?
Attendant operation, although recognized by the ASME A18.1 Standard, is expressly prohibited by the ADA Standards....
-
11B-405.5 Clear width
[2010 ADA Standards] 405.5 Clear Width. The clear width of a ramp run and, where handrails are provided, the clear width between handrails shall be 36 inches (915 mm) minimum....
-
11B-607.4 Grab bars
[2010 ADA Standards] 607.4 Grab Bars. Grab bars for bathtubs shall comply with 609 and shall be provided in accordance with 607.4.1 or 607.4.2. Exceptions: 1. Reserved....
-
11B-405.2 Slope
[2010 ADA Standards] EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes steeper than 1:12 complying with Table 405.2 where such...
-
11B-607.4 Grab bars
[2010 ADA Standards] 607.4 Grab Bars. Grab bars for bathtubs shall comply with 609 and shall be provided in accordance with 607.4.1 or 607.4.2. Exceptions: 1. Reserved....
-
11B-405.5 Clear width
[2010 ADA Standards] 405.5 Clear Width. The clear width of a ramp run and, where handrails are provided, the clear width between handrails shall be 36 inches (915 mm) minimum....
-
11B-405.2 Slope
[2010 ADA Standards] EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes steeper than 1:12 complying with Table 405.2 where such...
-
Valet Parking and Mechanical Access Parking Garages
The 1991 Standards, at sections 4.1.2(5)(a) and (e), and sections 208.2, 209.4, and 209.5 of the 2010 Standards require parking facilities that provide valet parking services to have an...
-
Noncomplying new construction and alterations
The element-by-element safe harbor referenced in Sec. 36.304(d)(2) has no effect on new or altered elements in existing facilities that were subject to the 1991 Standards on the date that...
-
Sections 505.10.2 and 505.10.3
Sections 505.10.2 and 505.10.3 of the 2010 Standards require handrail extensions at both the top and bottom of a flight of stairs....
-
Noncomplying new construction and alterations
The element-by-element safe harbor referenced in Sec. 35.150(b)(2) has no effect on new or altered elements in existing facilities that were subject to the 1991 Standards or UFAS on the...
-
F. Swimming Pool Entrance and Deck
Swimming Pool Entrance and Deck (1) Defendants will install a self-operated pool lift complying with 2010 ADA Standards §§ 242.2 and 1009.2 at the main swimming pool....
-
Noncomplying new construction and alterations. (Section-by-Section Analysis)
The element-by-element safe harbor referenced in Sec. 36.304(d)(2) has no effect on new or altered elements in existing facilities that were subject to the 1991 Standards on the date that...
-
Noncomplying new construction and alterations. (Section-by-Section Analysis)
The element-by-element safe harbor referenced in § 35.150(b)(2) has no effect on new or altered elements in existing facilities that were subject to the 1991 Standards or UFAS on the date...
-
Platform Lifts in Transient Lodging Guest Rooms and Dwelling Units
The 1991 Standards, at section 4.1.3(5), exception 4, and the 2010 Standards, at sections 206.7 and 206.7.6, both limit the locations where platform lifts are permitted to be used as part...
-
202.3.1 Prohibited Reduction in Access
(c) If the 2010 Standards reduce the technical requirements or the number of required accessible elements below the number required by the 1991 Standards, the technical requirements or the...
-
Where Required: Multi-Story Buildings and Facilities [§206.2.3]
However, if a building does qualify for an exception in the Standards: all other provisions in the Standards still apply to stories and mezzanines not served by an accessible route...
-
4. My pool already existed before the effective date of the new rule. What am I required to do to provide pool access to customers with mobility disabilities?
The 2010 Standards provide the benchmark, or goal, for accessibility in existing pools. (See Question 2 for the 2010 Standards requirements for pools)....
-
201.1 Scope
This code establishes standards for accessibility to places of public accommodation and commercial facilities by individuals with disabilities....
-
B. Advisory Committee and Final Report (2006-2008)
In the years following our initial promulgation of the 508 Standards and 255 Guidelines, technology continued to evolve at a rapid pace....
-
5. Medical Diagnostic Equipment
On January 9, 2017, new accessibility standards were published in the Federal Register for medical diagnostic equipment....
-
General: ADA Standard Section 221.1
Section 221.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for assembly areas.