At accessible parallel parking spaces, parking meters shall be located at the head or foot of the parking space. Advisory R309.5.1 Location....
Search Results "Clear Deck Space"
Commonly Searched Documents
-
R309.5.1 Location
-
§ 36.302(f)(4)(iii) Sales limited to fewer than four tickets
tickets to fewer than four seats per patron, then the public accommodation is only obligated to offer as many seats to patrons with disabilities, including the ticket for the wheelchair space...
-
1012.3 Other Vehicles
This section requires parking spaces for vehicles, other than recreational vehicles, to be 16 feet wide minimum to accommodate vans equipped with a lift or ramp....
-
§ 36.302(f)(9)(ii)
(ii) For group sales, if a group includes one or more individuals who use a wheelchair, the group shall be placed in a seating area that includes wheelchair spaces so that, if possible,...
-
§ 35.138(i)(2)
(2) For group sales, if a group includes one or more individuals who use a wheelchair, the group shall be placed in a seating area that includes wheelchair spaces so that, if possible, the...
-
Identification of available accessible seating. (Section-by-Section Analysis)
The proposed rule specifically prohibits the practice of "steering" individuals with disabilities to certain wheelchair spaces so that the facility can maximize potential ticket sales for...
-
M303.2.3.3 Side Entry
Where wheelchair space entry is only from the side, the wheelchair space shall be 60 inches (1525 mm) deep minimum....
-
11B-703.3.2 Position
Editor's Note 2013 CBC Figure 11B-703.3.2 is not intended to suggest that Braille must be multi-lined when the related text is multi-lined, only to illustrate the required position and spacing...
-
11B-703.3.2 Position
ETA Editor's Note CBC Figure 11B-703.3.2 is not intended to suggest that Braille must be multi-lined when the related text is multi-lined, only to illustrate the required position and spacing...
-
11B-703.3.2 Position
Editor's Note CBC Figure 11B-703.3.2 is not intended to suggest that braille must be multi-lined when the related text is multi-lined, only to illustrate the required position and spacing...
-
11B-503.5 Vertical clearance
Vehicle pull-up spaces, access aisles serving them, and a vehicular route from an entrance to the passenger loading zone and from the passenger loading zone to a vehicular exit shall provide...
-
M303.2.3.1 Front or Rear Entry
Where wheelchair space entry and exit is provided at only one end (front or rear) the wheelchair space shall be 48 inches (1220 mm) deep minimum....
-
M303.2.3.2 Pass Through Entry
Where wheelchair space entry and exit permits pass through from one end to the other, the wheelchair space shall be 40 inches deep (1015 mm) minimum....
-
Looking at Cal Green 5.106.5.3, we must provide the conduits and panel capacity for future installation for the required number of spaces (2 in this case). However, it is only when the equipment is to be installed that we need to refer to CBC and CEC. Section 11B-228.3.1 also reiterates this. Therefore, we would show the location of the conduit stub outs adjacent to 2 current parking spaces and would show space on the electric panel for the future equipment – and that is all. At this time, we do not need to show the requirements for EV accessibility when equipment is installed per Chapter 11B. Is my interpretation correct?
RESPONSE: CBC Chapter 11B accessibility provisions for EVCS apply when a project consists of one or more electric vehicle charging spaces served by an electric vehicle charger or other charging...
-
ATM Clear Floor or Ground Space
Sections 707.2 and 707.3 address clear floor or ground space requirements and operable parts, respectively. These provisions include exceptions for drive-up only ATMs....
-
F202.6.2 Accessible Route
Elements and spaces required to be accessible by F202.6 shall be on an accessible route complying with F206....
-
Resting Intervals [1017.8]
A turning space that complies with section 304.3.2 of the ABA Standards must be provided....
-
Attachment I
Provide at least 1 wheelchair seating area, each with a minimum clear ground or floor space of 66 inches wide by 48 inches deep for forward or rear access, or 66 inches wide by 60 inches...
-
11B-812.7.2 Marking
Access aisles at vehicle spaces shall be marked with a painted borderline around their perimeter....
-
§ 38.179(b)
In addition, each such unit shall comply with §38.23 (b) or (c) and shall provide at least one space for wheelchair or mobility aid users complying with §38.23(d) of this part unless the...
-
Figure M4: Overview of M303 Diagnostic Equipment for Use by a Patient While Seated in a Wheelchair and M304 Diagnostic Equipment for Use by a Patient in a Standing Position (Weight Scale Example)
Where the primary use of the equipment supports more than one patient position, it must comply with the requirements for each use. The weight scale is usable by both people who are...
-
Section E: Route from Entrance
. (§402.2) E8 If doors are provided along the route to the voting area, is the clear width of each door opening (one door or one active...
-
1012.5 Slope
The slope of the surface of parking spaces and pull-up spaces shall not be steeper than 1:48 in any direction....
-
Opening Doors From a Wheelchair Video
Requires the Registered User plan or above. Login!