When the lift is at car floor height with the inner barrier down (if applicable) or retracted, gaps between the forward lift platform edge and car floor shall not exceed 1/2 inch horizontally...
Search Results "Input Floor"
-
§ 38.95(b)(7) Platform gaps
-
§ 38.125(b)(7) Platform gaps
When the lift is at car floor height with the inner barrier (if applicable) down or retracted, gaps between the forward lift platform edge and car floor shall not exceed 1/2 inch horizontally...
-
11B-407.4.8.2.1 Signal type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop....
-
A. Accessibility of Web Information
On May 9, 2016, the Department published a Supplemental Advance Notice of Proposed Rulemaking (SANPRM) regarding title II Web accessibility to seek additional public input regarding a wide...
-
b. Positioning Supports
The Access Board noted in the MDE NPRM preamble that it was considering adding positioning supports to the final rule and sought public input with question 24 on whether positioning supports...
-
M301.4 Lift Compatibility (Section-by-Section Analysis)
Additionally, question 27 in the MDE NPRM preamble requested input on whether the final rule should provide an exception from the lift compatibility requirements where the diagnostic equipment...
-
FAQ: How do I sign up for multiple subscriptions for me, my colleagues, co-workers or staff?
Continue until all users are input. Click "Submit." The system will automatically notify the users they have been added to your subscription....
-
Waviness Index
Waviness Index The Waviness Index, ASTM E 1486, Standard Test Method for Determining Floor Tolerances Using Waviness, Wheel Path and Levelness Criteria, was developed in response to the...
-
11B-604.8.1.4 Toe clearance
At least one side partition shall provide a toe clearance of 9 inches (229 mm) minimum above the finish floor and 6 inches (152 mm) deep minimum beyond the compartment-side face of the partition...
-
11B-604.8.1.4 Toe clearance
At least one side partition shall provide a toe clearance of 9 inches (229 mm) minimum above the finish floor and 6 inches (152 mm) deep minimum beyond the compartment-side face of the partition...
- TelCom Wheelock Wall Mount Chime - 24 VDC 15/75 on Axis Strobe Candela CH70-241575W-FR
-
Temporary Solutions for Election Day - Hallways and Corridors - Voters Who are Blind or Who Have Low Vision
The bottom of the skirting or detectable object must be no higher than 27 inches above the floor....
-
4.1.3(17)(a)
are provided, then they shall comply with 4.31.2 through 4.31.8 to the extent required by the following table: Number of each type of telephone provided on each floor...
-
OVERVIEW
The input of people who are deaf or hard of hearing who are involved in incidents is just as important to the law enforcement process as the input of others. ...
-
11B-603.4 Coat hooks, shelves and medicine cabinets
Shelves shall be located 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor....
-
11B-308.3.1 Unobstructed
Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1219 mm) maximum and the low side...
-
4.4.1* General
Objects projecting from walls (for example, telephones) with their leading edges between 27 in and 80 in (685 mm and 2030 mm) above the finished floor shall protrude no more than 4 in (100...
-
Destination-Oriented Elevators
Destination-oriented elevators are different from typical elevators in that they provide a means of indicating the desired floor at the location of the call button, usually through a key...
-
11B-704.2.1.2 Forward approach
Where a forward approach is provided at a telephone within an enclosure, the counter may extend beyond the face of the telephone 20 inches (508 mm) into the required clear floor or ground...
-
11B-605.4 Flush controls
Hand operated flush controls shall comply with Section 11B-309 except that the flush control shall be mounted at a maximum height of 44 inches (1118 mm) above the finish floor. ...
-
Obstructed High Reach: ADA Standard Section 308.2.2
Section 308.2.2 covers the current ADA Standards for obstructed high reach.
-
Visible and Audible Signals: ADA Standard Section 407.2.2.1
Section 407.2.2.1 covers the current ADA Standards for elevator visible and audible signals.
-
Identification: ADA Standard Section 502.6
Section 502.6 covers the current ADA Standards for parking space identification signs.
-
11B-604.9.6 Dispensers
The outlet of the dispenser shall be 14 inches (356 mm) minimum and 19 inches (483 mm) maximum above the finish floor....