[ADA Standards § 4.13.5] Yes No...
Search Results "Brand Standards"
-
H25
-
§ 35.150(b)(5)(ii)
(ii) Where an existing swimming pool has less than 300 linear feet of swimming pool wall, it shall be exempt from the provisions of section 242.2 of the proposed standards; and...
-
H11
[ADA Standards § 4.19.6] Yes No...
-
H23
[ADA Standards § 4.17.3] Yes No...
-
J4
[ADA Standards §§ 4.15.3 and 4.15.4] Yes No...
-
C1-c
[ADA Standards § 4.3.3] Yes No If No, does the accessible route narrow to 32 inches for no more than 2 feet?...
-
§ 36.406(e)(2)
Multi-bedroom housing units containing accessible sleeping rooms with mobility features shall have an accessible route throughout the unit in accordance with section 809.2 of the 2010 Standards...
-
§ 36.406(d)(1)
(1) In sleeping rooms with more than 25 beds covered by this section, a minimum of 5% of the beds shall have clear floor space complying with section 806.2.3 of the 2010 Standards....
-
Maintenance
Routine or periodic repair of trails or trail segments to restore them to the standards to which they were originally designed and built. ...
-
Must operable parts be usable with a closed fist?
Closed-fist operation is a good performance test but is not required by the standards....
-
Can audible signals for an elevator operate only when needed by a passenger who needs them through activation of dedicated “accessibility” control?
Requiring passengers to manually activate such signals when needed is not permitted by the ADA Standards....
-
§ 35.151(e)(1)
(1) In sleeping rooms with more than 25 beds covered by this section, a minimum of 5% of the beds shall have clear floor space complying with section 806.2.3 of the 2010 Standards....
-
§ 35.151(f)(2)
Multi-bedroom housing units containing accessible sleeping rooms with mobility features shall have an accessible route throughout the unit in accordance with section 809.2 of the 2010 Standards...
-
11B-407.4.6.2 Buttons
[2010 ADA Standards] EXCEPTION: In existing elevators, buttons shall be permitted to be recessed....
-
11B-407.2.3.2 Reserved
Editor's Note Imposing additional requirements regarding characters and colors, the preceding CBC requirements pertaining to elevator hoistway signs are more stringent than 2010 ADA Standards...
-
1008.2.6.2 Use Zones
Ground surfaces located within use zones shall comply with ASTM F 1292 (1999 edition or 2004 edition) (incorporated by reference, see "Referenced Standards" in Chapter 1)....
-
Cities and Counties: First Steps Toward Solving Common ADA Problems
New Construction and Alterations: Facilities constructed or altered after January 26, 1992, must comply with the ADA Standards for Accessible Design (ADA Standards), which are available...
-
Organization and Format
Some commenters felt that the Board should reference other codes and standards for greater consistency with the model building codes and that more cross references should be made to other...
-
1. General Exception
Section 510 of the Rehabilitation Act requires the MDE Standards to provide independent access “to the maximum extent possible.”...
-
Required Compliance [§206.6]
Each passenger elevator provided, whether required or not, must comply with the ADA Standards....
-
Re: 11B-216.6 Entrances
Notice that, for public entities under Title II, the language of the regulations is stricter than the Standards. ...
-
Wheelchair Space or Transfer Seat or Transfer Device
Sections 234.3 and 1002.4 - 1002.6 of the 2010 Standards provide that each new and altered amusement ride, except for mobile/portable rides and a few additional excepted rides, will be required...
-
New Construction and Alterations
These curb ramps must comply with the 2010 Standards.3 DOT’s Section 504 Federally assisted regulation also requires the provision of curb ramps in new construction and alterations. ...
-
Elevator Car Controls
Comments recommended that the height of elevator car controls be harmonized with the ANSI A117.1 standard....