RESPONSE: The accessibility provisions in CBC Chapter 11B do not permit a required accessible EVCS to be installed in a required accessible parking space....
Search Results "Building Permit"
Commonly Searched Documents
-
For small parking lots, is there any variance on being able to share EV charging with the existing accessible parking spaces?
-
Gates, Bars, and Berms
Forest Service-constructed barriers on pedestrian travel routes must have a 32-inch minimum width gap or include a route beside them that will permit passage of a wheelchair....
-
11B-411.2.1.4.1 Hall call console additional buttons
Buttons in addition to the accessibility function button are not permitted on hall call consoles using a touch screen....
-
11B-206.7.2 Wheelchair spaces
Platform lifts shall be permitted to provide an accessible route to comply with the wheelchair space dispersion and line-of-sight requirements of Sections 11B-221 _|Assembly Areas|_ and...
-
3.1.3.1 Slope of Vehicle Parking Areas
When the surface is not paved, slopes not steeper than 1:33 (3 percent) shall be permitted where necessary for drainage. ...
-
1018.7.2 Cross Slope
Where the surface is other than asphalt, concrete, or boards, cross slopes not steeper than 1:20 are permitted when necessary for drainage....
-
6.6 Clear Width
Exception: At dune crossings, the clear width of beach access routes that are not removable shall be permitted to be reduced to 48 inches (1220 mm) minimum....
-
2.4.1.3
A grade of up to 1:10 (10 percent) is permitted for up to 30 feet (9 m) of an ORAR....
-
1011.2.3 Slope
Where the surface is other than asphalt, concrete, or boards, slopes not steeper than 1:20 are permitted when necessary for drainage....
-
2.4.1.2
A grade of up to 1:12 (8.33 percent) is permitted for up to 50 feet (15 m) of an ORAR....
-
1018.4 Clear Width
EXCEPTION: At dune crossings, the clear width of beach access routes that are not removable shall be permitted to be reduced to 48 inches (1220 mm) minimum....
-
11B-411.2.1.4.1 Hall call console additional buttons
Buttons in addition to the accessibility function button are not permitted on hall call consoles using a touch screen....
-
§ 35.136(g) Access to areas of a public entity
Individuals with disabilities shall be permitted to be accompanied by their service animals in all areas of a public entity's facilities where members of the public, participants in services...
-
11B-406.5.6 Grade breaks
Grade breaks shall not be permitted on the surface of ramp runs and turning spaces. Surface slopes that meet at grade breaks shall be flush....
-
11B-604.1 General
Exception: Water closets and toilet compartments for children's use shall be permitted to comply with Section 11B-604.9....
-
11B-206.7.2 Wheelchair spaces
Platform lifts shall be permitted to provide an accessible route to comply with the wheelchair space dispersion and line-of-sight requirements of Sections 11B-221 _|Assembly Areas|_ and...
-
11B-406.5.6 Grade breaks
Grade breaks shall not be permitted on the surface of ramp runs and turning spaces. Surface slopes that meet at grade breaks shall be flush....
-
11B-411.2.1.4.1 Hall call console additional buttons
Buttons in addition to the accessibility function button are not permitted on hall call consoles using a touch screen....
-
1007.12 Alarms/emergency warning systems/accessibility
ETA Editor's Note Sections from California Building Code Chapter 10 not adopted by Division of the State Architect - Access Compliance (DSA-AC) omitted. ...
-
Vertical Access to Mezzanines
mezzanines where provided, ADAAG has not been clear on whether some form of vertical access is nonetheless required to a mezzanine level where no elevator is provided, such as a one-story building...
-
1007.8 Exterior area for assisted rescue
Where walls or openings are between the area for assisted rescue and the interior of the building, the building exterior walls within 10 feet (3048 mm) horizontally of a nonrated wall or...
-
1003.2.13.7 Exterior area for assisted rescue
Where walls or openings are between the area for assisted rescue and the interior of the building, the building exterior walls within 10 feet (3048 mm) horizontally of a nonrated wall or...
-
Starting Your Plan with Preparedness
Use the plan template that is part of this toolkit to capture important information and decisions to build your plan....
-
4.28.3* VISUAL ALARMS
If such alarms use electricity from the building as a power source, then they shall be installed on the same system as the audible emergency alarms....