in accordance with 208.2.3.2 shall not be required to be dispersed throughout all types of parking if substantially equivalent or greater accessibility is provided in terms of distance from...
Search Results "Assurances from Contractors"
-
208.3.2 Residential Facilities
-
608.5.3 Alternate Roll-In Type Shower Compartments
Where a seat is provided, the controls, faucets, and shower spray unit shall be located on the side wall adjacent to the seat 27 inches (685 mm) maximum from the side wall behind the seat...
-
11B-1009.2.4 Seat
The height of the lift seat shall be designed to allow a stop at 17 inches (432 mm) minimum to 19 inches (483 mm) maximum measured from the deck to the top of the seat surface when in the...
-
407.7 Color (Section-by-Section Analysis)
407.7 Color (Section-by-Section Analysis) This section proposes to prohibit color-coding from being the only means of conveying information, indicating an action, prompting a response...
-
4.4.1* General
Objects projecting from walls (for example, telephones) with their leading edges between 27 in and 80 in (685 mm and 2030 mm) above the finished floor shall protrude no more than 4 in (100...
-
Doorways [4.8.4]
Recommendation: Ramps and doors should be configured to facilitate wheelchair maneuvering and to prevent open doors from obstructing ramp openings (important along egress routes)....
-
F201.4.1 Documentation and Notification When Exceptions Used for Trails and Beach Access Routes
Federal agencies shall notify the Access Board if an entire trail is exempted from complying with 1017 based on Exception 2 in 1017.1, and if a beach access route is not provided based on...
-
4.10.4 HALL LANTERNS
(3) Signals shall be visible from the vicinity of the hall call button....
-
19.
Venture Hotels constructed for first occupancy after January 26, 1993, HWI shall (to the extent it has the contractual right to do so) (i) require the hotel owner to submit a certification from...
-
11B-608.3.2 Standard roll-in type shower compartments
Grab bars shall be installed 6 inches (152 mm) maximum from adjacent walls. [2010 ADAS] 608.3.2 Standard Roll-In Type Shower Compartments....
-
Stairs
Result: People who use crutches or a cane or who have limited balance may fall at the top or bottom of the stairs because they have no railing to hold onto as they make the transition from...
-
CHAPTER 11A HOUSING ACCESSIBILITY
ETA Editor's Note Sections from California Building Code Chapter 11A not adopted by Division of the State Architect - Access Compliance (DSA-AC) omitted....
-
§ 38.57(b)
Ample vertical stanchions from ceiling to seat-back rails shall be provided....
-
11B-203.2 Construction sites
This section provides a general exception for structures and sites directly associated with the actual processes of construction from the accessibility provisions of Chapter 11B....
-
CHAPTER 11A HOUSING ACCESSIBILITY
ETA Editor's Note Sections from California Building Code Chapter 11A that are not adopted by Division of the State Architect - Access Compliance (DSA-AC) have been omitted....
-
11B-812.10.4 Location
path is not provided adjacent to the head end of the vehicle space or access aisle, the EV charger may be located within the projected width of the access aisle 36 inches (914 mm) maximum from...
-
11B-203.2 Construction sites
This section provides a general exception for structures and sites directly associated with the actual processes of construction from the accessibility provisions of Chapter 11B....
-
1009.3.3 Area of Refuge
Stairways shall either incorporate an area of refuge within an enlarged floor-level landing or shall be accessed from an area of refuge complying with Section 1009.6....
-
1. GENERAL
educational facilities, and any other facilities where civilian workers may be employed, including facilities constructed under other than military construction authorizations and including contractor-owned...
-
DEFINITIONS
The term "THE CREDIT UNION employees" shall mean individuals employed by THE CREDIT UNION and contractors working for THE CREDIT UNION....
-
§1607.11 Disparate treatment.
The principles of disparate or unequal treatment must be distinguished from the concepts of validation....
-
1136A.1 Receptacle heights
Electrical receptacle outlets on branch circuits of 30 amperes or less and communication system receptacles shall be located no more than 48 inches (1219 mm) measured from the top of the...
-
Issue: Local Laws, Ordinances, and Regulations
For example, where a municipal zoning ordinance requires a set-back of 12 feet from the curb in the central business district, installing a ramp to ensure access for people who use wheelchairs...
-
R210.3 Shared Use Paths
Objects shall not overhang or protrude into any portion of a shared use path at or below 2.4 m (8.0 ft) measured from the finish surface....