inches (229 mm) and 27 inches (686 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches (152 mm) in height...
Search Results "Adjustable Height Counter"
-
11B-306.3.4 Clearance reduction
-
1132A.1 Primary entry doors and required exit doors
The width and height of primary entry doors and all required exit doors shall comply with Section 1126A.1....
-
Notes
accessing a health care provider’s office because of its physical layout or location. (5) being treated unfairly at a health care provider’s office.23 I The methods for measuring “low heights...
- AJW Architectural Products UG120-U Series UG120-U 29" Swing-Up, 1.25" Diameter Grab Bar - Configuration U
-
1125B.3
SECTION 1125B - STORAGE 1125B.3 Height. Accessible storage spaces shall be within at least one of the reach ranges specified in Sections 1118B.5 and 1118B.6....
-
Notes
Notes GG Analysis of Seat Heights for Wheeled Mobility Devices. The study is available at http://udeworld.com/analysis-of-seat-height-for-wheeled-mobility-devices....
-
Medical Diagnostic Equipment Accessibility Standards Sub Committee Recommendations Stretcher Final Report
Features Addressed in Technical Criteria Types Of Equipment To Which Technical Criteria Applies Supine, prone, or side-lying position (M301) Transfer surface, including height...
-
1134A.5, Item 2
The grab bar reinforcement shall be a minimum of 6 inches (152.4 mm) nominal in height. (See Figure 11A-9G)....
-
1016.5 Obstacles
This section requires obstacles to not exceed 1/2 inch in height measured vertically to the highest point....
-
1134A.5, Item 2
The grab bar reinforcement shall be a minimum of 6 inches (152.4 mm) nominal in height. (See Figure 11A-9G)....
-
ALTERATION
resurfacing of circulation paths or vehicular ways, changes or rearrangement of the structural parts or elements, and changes or rearrangement in the plan configuration of walls and full-height...
-
11B-306.3.3 Minimum required depth
high minimum above the finish floor or ground at a depth of 8 inches (203 mm) minimum increasing to 29 inches (737 mm) high minimum above the finish floor or ground at the front edge of a counter...
-
Technical Memorandum TM 2013-22 Storage (Kitchens and Kitchenettes)
Counter surfaces shall not be considered shelf space nor used to satisfy the requirements of 804.5....
-
A. Changes in Level
.: back of registration counter, housekeeping storage rooms, kitchens, administrative offices, etc.) Yes __ No __ N/A __ Comments: ___________________________________________...
-
11B-306.3.3 Minimum required depth
high minimum above the finish floor or ground at a depth of 8 inches (203 mm) minimum increasing to 29 inches (737 mm) high minimum above the finish floor or ground at the front edge of a counter...
-
11B-306.3.3 Minimum required depth
high minimum above the finish floor or ground at a depth of 8 inches (203 mm) minimum increasing to 29 inches (737 mm) high minimum above the finish floor or ground at the front edge of a counter...
-
1132A.4, Item 4
., concrete, brick, flagstone) may have a maximum change in height from the interior landing of 1 inch (25.4 mm), provided a ramp with a maximum slope of 1:8 is permanently installed....
-
11B-502.8.2 Lettering
The additional sign shall clearly state in letters with a minimum height of 1 inch (25 mm) the following: "Unauthorized vehicles parked in designated accessible spaces not displaying...
-
11B-605.4 Flush controls
Hand operated flush controls shall comply with Section 11B-309 except that the flush control shall be mounted at a maximum height of 44 inches (1118 mm) above the finish floor....
-
4.10.12(3)
(3) Height. All floor buttons shall be no higher than 54 in (1370 mm) above the finish floor for side approach and 48 in (1220 mm) for front approach....
-
Scoping [4.1.3(20)]
Specifications in 4.34.2 and 4.34.3 were modified in June 1993 to allow either a forward or side approach and to provide further guidance on side reach heights....
-
A4.13.9 Door Hardware
To be effective, they should cover the door width, less approximately 2 in (51 mm), up to a height of 16 in (405 mm) from its bottom edge and be centered across the width of the door....
-
604.5 Grab Bars
must be sufficient to permit the installation of rear and side wall grab bars that fully meet all accessibility requirements including, but not limited to, required length, installation height...