Visible alarm notification appliances shall be provided in public use areas and common use areas, including but not limited to: Sanitary facilities including restrooms, bathrooms...
Search Results "Visibility"
Commonly Searched Documents
-
[F] 907.5.2.3.1 Public and common use areas
-
11B-809.5.3 Interconnection
The same visible alarm appliances shall be permitted to provide notification of residential dwelling unit smoke detection and building fire alarm activation, and carbon monoxide detection...
-
11B-809.5.3 Interconnection
The same visible alarm appliances shall be permitted to provide notification of residential dwelling unit smoke detection, building fire alarm activation, and carbon monoxide detection....
-
[2010 ADAS] 105.2.5 NFPA
NFPA 72 specifies characteristics for visible alarms, such as flash frequency, color, intensity, placement, and synchronization....
-
11B-215.1 General
Exception: In existing facilities, visible alarms for fire alarm systems shall not be required except where an existing fire alarm system is upgraded or replaced, or a new fire alarm system...
-
F215.3 Employee Work Areas
Where employee work areas have audible alarm coverage, the wiring system shall be designed so that visible alarms complying with 702 can be integrated into the alarm system....
-
215.3 Employee Work Areas
Where employee work areas have audible alarm coverage, the wiring system shall be designed so that visible alarms complying with 702 can be integrated into the alarm system....
-
Can audible signals for an elevator operate only when needed by a passenger who needs them through activation of dedicated “accessibility” control?
No, audible (and visible) signals required for elevators must function automatically at all times an elevator is operational....
-
11B-812.7.3 Lettering
The words “NO PARKING” shall be painted on the surface within each access aisle in letters a minimum of 12 inches (305 mm) in height and located to be visible from the adjacent vehicular...
-
11B-812.7.3 Lettering
The words “NO PARKING” shall be painted on the surface within each access aisle in letters a minimum of 12 inches (305 mm) in height and located to be visible from the adjacent vehicular...
-
General: ADA Standard Section 702.1
Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 (1999 or 2002 edition) (incorporated by reference, see “Referenced Standards” in Chapter...
-
230 and 708 Two-Way Communication Systems
230 and 708 Two-Way Communication Systems New provisions of the 2010 Standards at sections 230.1 and 708 require two-way communications systems to be equipped with visible as well as...
-
809.5.4 Prohibited Use
Visible alarm appliances used to indicate residential dwelling unit smoke detection or building fire alarm activation shall not be used for any other purpose within the residential dwelling...
-
809.5.4 Prohibited Use
Visible alarm appliances used to indicate residential dwelling unit smoke detection or building fire alarm activation shall not be used for any other purpose within the residential dwelling...
-
M306 Communication
communicates instructions or other information to the patient, M306 would require the instructions or other information to be provided in at least two of the following methods: audible, visible...
-
Section I: Elevators
(§§407.4.6.1, 308.2, 308.3) I5 Does the elevator have visible and audible signals in the hallway to indicate the arrival and direction of...
-
215.3 Employee Work Areas
Where employee work areas have audible alarm coverage, the wiring system shall be designed so that visible alarms complying with 702 can be integrated into the alarm system....
-
M306.1 General
diagnostic procedure is communicated to the patient through the diagnostic equipment, the instructions and other information shall be provided in at least two of the following methods: audible, visible...
-
R309.5.2 Displays and Information
Displays and information shall be visible from a point located 1.0 m (3.3 ft) maximum above the center of the clear space in front of the parking meter or parking pay station....
-
11B-502.8 Additional signage
An additional sign shall be posted either; 1) in a conspicuous place at each entrance to an off-street parking facility or 2) immediately adjacent to on-site accessible parking and visible...
-
11B-502.8 Additional signs
An additional sign shall be posted either; 1) in a conspicuous place at each entrance to an off-street parking facility or 2) immediately adjacent to on-site accessible parking and visible...
-
11B-502.8 Additional signs
An additional sign shall be posted either; 1) in a conspicuous place at each entrance to an off-street parking facility or 2) immediately adjacent to on-site accessible parking and visible...
-
809.5.1.2 Activation
All visible alarm appliances provided within the residential dwelling unit for building fire alarm notification shall be activated upon activation of the building fire alarm in the portion...
-
11B-809.5.4 Prohibited use
Visible alarm appliances used to indicate residential dwelling unit smoke detection, carbon monoxide detection, or building fire alarm activation shall not be used for any other purpose...