Group R-1 and R-2.1 dwelling units or sleeping units in accordance with Table 907.5.2.3.3 shall be provided with a visible alarm notification appliance, activated by both the in-room smoke...
Search Results "Visibility"
-
[F] 907.5.2.3.3 Groups R-1 and R-2.1
-
[F] 907.5.2.3.2 Groups R-1 and R-2.1
Group R-1 and R-2.1 dwelling units or sleeping units in accordance with Table 907.5.2.3.2 shall be provided with a visible alarm notification appliance, activated by both the in-room smoke...
-
11B-702.1 General
Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 and Chapter 9, Sections 907.5.2.1 and 907.5.2.3....
-
11B-702.1 General
Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 and Chapter 9, Sections 907.5.2.1 and 907.5.2.3....
-
806.3.2 Notification Devices
Visible notification devices shall be provided to alert room occupants of incoming telephone calls and a door knock or bell....
-
11B-215.3 Employee work areas
Where employee work areas have audible alarm coverage, the wiring system shall be designed so that visible alarms complying with Chapter 9, Section 907.5.2.3.1 Exception can be integrated...
-
11B-215.3 Employee work areas
Where employee work areas have audible alarm coverage, the wiring system shall be designed so that visible alarms complying with Chapter 9, Section 907.5.2.3.1 Exception can be integrated...
-
Tread Width
The visible trail surface measured perpendicular to the direction of travel....
-
11B-806.3.2 Notification devices
Visible notification devices shall be provided to alert room occupants of incoming telephone calls and a door knock or bell....
-
11B-806.3.2 Notification devices
Visible notification devices shall be provided to alert room occupants of incoming telephone calls and a door knock or bell....
-
11B-809.5.4 Prohibited use
Visible alarm appliances used to indicate residential dwelling unit smoke detection, carbon monoxide detection, or building fire alarm activation shall not be used for any other purpose...
-
11B-806.3.2 Notification devices
Visible notification devices shall be provided to alert room occupants of incoming telephone calls and a door knock or bell....
-
F215.1 General
EXCEPTION: In existing facilities, visible alarms shall not be required except where an existing fire alarm system is upgraded or replaced, or a new fire alarm system is installed....
-
215.1 General
EXCEPTION: In existing facilities, visible alarms shall not be required except where an existing fire alarm system is upgraded or replaced, or a new fire alarm system is installed....
-
215.1 General
EXCEPTION: In existing facilities, visible alarms shall not be required except where an existing fire alarm system is upgraded or replaced, or a new fire alarm system is installed....
-
[F] 907.5.2.3.1 Public and common use areas
Visible alarm notification appliances shall be provided in public use areas and common use areas, including but not limited to: Band rooms Classrooms Corridors...
-
[F] 907.5.2.3.1 Public and common use areas
Visible alarm notification appliances shall be provided in public use areas and common use area, including but not limited to: Band rooms Classrooms Corridors Gymnasiums Lobbies...
-
1009.8.1 System requirements
The two-way communication system shall include both audible and visible signals. Systems shall be listed in accordance with UL 2525 and installed in accordance with NFPA 72....
-
11B-411.4.8 Car position indicators
Audible and visible car position indicators shall be provided in elevator cars....
-
11B-411.4.8 Car position indicators
Audible and visible car position indicators shall be provided in elevator cars....
-
11B-411.4.8 Car position indicators
Audible and visible car position indicators shall be provided in elevator cars....
-
412.6 Caller ID
Where provided, caller identification and similar telecommunications functions shall be visible and audible....
- Seton Florida State Parking Signs - ISA Symbol
-
11B-215.1 General
Exception: In existing facilities, visible alarms for fire alarm systems shall not be required except where an existing fire alarm system is upgraded or replaced, or a new fire alarm system...