Call buttons in elevator lobbies and halls shall be centered at 42 in (1065 mm) above the floor....
Search Results "Pedestrian Traffic Control Button"
Commonly Searched Documents
-
4.10.3 Hall Call Buttons
-
4.10.3 HALL CALL BUTTONS
Call buttons in elevator lobbies and halls shall be centered at 42 in (1065 mm) above the floor....
-
Location: ADA Standard Section 407.4.7.1.2
Section 407.4.7.1.2 covers the current ADA Standards for the location of designations and indicators on elevator car control buttons.
-
Exceptions for Specific Occupancies [§206.2.3]
Exceptions for Specific Occupancies [§206.2.3] The Standards also include limited exceptions for accessible routes between stories in air traffic control towers and, under certain...
-
11B-206.4.3 Entrances from tunnels or elevated walkways
Where direct access is provided for pedestrians from a pedestrian tunnel or elevated walkway to a building or facility, all entrances to the building or facility from each tunnel or walkway...
-
11B-411.2.1.2.3 Accessibility function button
11B-411.2.1.2.3 Accessibility function button. The accessibility function button shall be identified by the International Symbol of Accessibility and a raised indication....
-
1. Access Barrier Removal in Existing Pedestrian Facilities
Access Barrier Removal in Existing Pedestrian Facilities The Settlement Agreement requires the City to spend approximately $1.37 billion over the next thirty (30) years to implement...
-
11B-411.2.1.2.3 Accessibility function button
The accessibility function button shall be identified by the International Symbol of Accessibility and a raised indication....
-
11B-411.2.1.3.1 Keypad call console arrangement
The accessibility function button shall be located directly below the keypad at a height of 36 inches (914 mm) to 42 inches (1067 mm) above the finish floor....
-
Entrances from Tunnels or Elevated Walkways: ADA Standard Section 206.4.3
Section 206.4.3 covers scoping requirements in the most current ADA Standards for accessible routes to entrances from tunnels or elevated walkways.
-
Car Controls
...are the highest floor control buttons in the elevator(s) mounted within 54" of the floor, with associated raised letters and Braille characters?...
-
If no pedestrian route onto a site is provided, is an accessible route still required?
An accessible route from the boundary of the site is not required where the only means of site arrival is a vehicular way without pedestrian access....
-
Proposed Guidelines Developed Specifically for Pedestrian Facilities in the Public Right-of-Way
Proposed Guidelines Developed Specifically for Pedestrian Facilities in the Public Right-of-Way The proposed guidelines are developed specifically for pedestrian facilities in the public...
-
4.7.6 Built-up Curb Ramps
Built-up curb ramps shall be located so that they do not project into vehicular traffic lanes (see Fig. 13)....
-
4.7.6 BUILT-UP CURB RAMPS
Built-up curb ramps shall be located so that they do not project into vehicular traffic lanes (see Fig. 13)....
-
Volume Control
All public telephones are required to be equipped with volume control, as discussed above in section 217....
-
Car Controls [§407.4.6 and §407.4.7]
Car Controls [§407.4.6 and §407.4.7] If more than one car control panel is provided in a car, both must comply (except in existing cars where only 1 panel must comply)....
-
11B-602.9 Pedestrian protection
All drinking fountains shall either be located completely within alcoves, positioned completely between wing walls, or otherwise positioned so as not to encroach into pedestrian ways....
-
11B-602.9 Pedestrian protection
All drinking fountains shall either be located completely within alcoves, positioned completely between wing walls, or otherwise positioned so as not to encroach into pedestrian ways....
-
11B-411.2.1.2.3 Accessibility function button
The accessibility function button shall be identified by the International Symbol of Accessibility and a raised indication....
-
11B-407.4.6.2.2 Arrangement
Buttons shall be arranged with numbers in ascending order. When two or more columns of buttons are provided they shall read from left to right....
-
11B-407.4.7.1.1 Type
Control buttons shall be identified by raised characters or symbols, white on a black background, complying with Section 11B-703.2 and Braille complying with Section 11B-703.3....
-
11B-407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3...
-
R302.5 Grade
Except as provided in R302.5.1, where pedestrian access routes are contained within a street or highway right-of-way, the grade of pedestrian access routes shall not exceed the general grade...